Digitax ST User Guide
61
Issue: 5
Figure 7-1 Minimum connections to get the motor running via Serial Communications (e.g. CTSoft)
U V W
30
31
28
29
26
27
24
25
23
21
22
SAFE TORQUE
OFF(drive
enable - T31)
24V
U V W
A A
B B
U U
V V
W W
Z Z
Encoder connector
15 way D-type
5
10
15
1
6
11
Serial
communications
port
External
braking
resistor
(optional)
L3/N
L2
L1
L2
L1
Fuses
Serial Comms
User Interface
Isolated serial
comms lead
DST12XX = 200 to 240V 10%
DST14XX = 380 to 480V 10%
±
±
Part number
Description
CT EIA232
Comms cable
CT USB
Comms cable
4500-0087
4500-0096
Internal
braking
resistor
(optional)
Thermal
overload
protection
device
Polarized signal
connections
Terminals
Torque setting*
Power terminals
1.0 N m
(12.1 lb in)
Control terminals
0.2 N m
(1.7 lb in)
Status relay
terminals
0.5 N m
(4.5 lb in)
Ground terminal
screws
4 N m
(35 lb in)
Small ground
terminal screws
2 Nm
(17.7 Ib in)
* Torque tolerance = 10%