EOS Zeus HD / Zeus L HD - Installation and Operating Instructions
EN-43
Maintenance
6.4 Troubleshooting
Error
Reason
Solution
It takes the heater a long time to heat
up the cabin.
Some tubular heating elements are
defective.
Replace the tubular heating element
or heating coil. See
6.3 Replacing the tubular heating
elements,
There is not enough space between
the stones.
Reshuffle the stones. See
There is insufficient ventilation.
Install the air inlets. If these are insuffi-
cient, add a fan to the openings. See
3.1.2 Air inlets and outlets,
The heater is very hot but cannot dis-
tribute the heat throughout the cabin.
There is not enough space between
the stones.
Reshuffle the stones. See
The safety temperature limiter was
triggered and the heater no longer
heats.
The safety temperature limiter was
triggered by heat accumulation.
Check the inlets, outlets, and the fan
and ensure that the heater has access
to a sufficient amount of air.
The position of the temperature sen-
sor with the safety temperature limiter
is not optimal.
Check the position of the temperature
sensor and adjust as needed. See
3.2 Installing the temperature
sensor,