19
GB
L1 L2 L3
N
Sensor
Limiter
S1
Saunasteuergerät
control unit
U V W WB WM N
400 V AC 3N
N U V W
max. 9 kW
Sensor
Example of a properly connected sauna system
Caution! Always make certain to connect
the neutral wire N.
U V W N PE
1500W
1500W
1500W
400 V AC 3N
4,5 kW
U V W N PE
2000W
2000W
2000W
400 V AC 3N
6 kW
U V W N PE
2500W
2500W
2500W
400 V AC 3N
7,5 kW
400 V AC 3N
PE
U V W N
1500W
1500W
1500W
1500W
1500W
1500W
9 kW
Capacity
acc. DIN
Electrical.
Connection
Fuse control
unit in A
For cabin size
Minimum
dimensions of
air intake and
exhaust vents
Connecting
cable main -
control unit
in mm²
Connecting
cable control
unit - heater
in mm²
Power switch
gear (LSG)
needed
For operation with control units
4,5 kW
3N AC
50 Hz
400 V
3 x 16
4 - 6 m³
35 x 3 cm
5 x 2,5²
5 x 1,5²
no
ECON D1, D2, D3, H1, H2, H3
EMOTEC DC9000
EMOTEC DC9000 DB/DL/DLF
EMOTEC HCS9003
EMOTEC HCS9003 DB/DL/DLF
EmoTouch II PB/AF/GF
6,0 kW
6 - 8 m³
35 x 4 cm
7,5 kW
7 - 10 m³
35 x 5 cm
9,0 kW
9 - 14 m³
35 x 6 cm
All cross sections of a line are minimum diameters in mm² (Copper line)