background image

19

GB

L1 L2 L3

N

Sensor

Limiter

S1 

Saunasteuergerät
control unit 

U  V W WB WM  N

400 V AC 3N

N U V W

max. 9 kW

Sensor

Example of a properly connected sauna system

Caution!  Always make certain to connect 
the neutral wire N.

U V W N PE

1500W

1500W

1500W

400 V AC 3N

4,5 kW

U V W N PE

2000W

2000W

2000W

400 V AC 3N

6 kW

U V W N PE

2500W

2500W

2500W

400 V AC 3N

7,5 kW

400 V AC 3N

PE

U V W N

1500W

1500W

1500W

1500W

1500W

1500W

9 kW

Capacity 

acc. DIN

Electrical. 

Connection

Fuse control 

unit in A

For cabin size

Minimum 

dimensions of 

air intake and 

exhaust vents

Connecting 

cable main - 

control unit 

in mm²

Connecting 

cable control 

unit - heater 

in mm²

Power switch 

gear (LSG) 

needed

For operation with control units

4,5 kW

3N AC

50 Hz

 400 V

3 x 16

4 - 6 m³

35 x 3 cm

5 x 2,5²

 5 x 1,5²

no

ECON D1, D2, D3, H1, H2, H3

EMOTEC DC9000

EMOTEC DC9000 DB/DL/DLF

EMOTEC HCS9003

EMOTEC HCS9003 DB/DL/DLF

EmoTouch II PB/AF/GF

6,0 kW

6 - 8 m³

35 x 4 cm

7,5 kW

7 - 10 m³

35 x 5 cm

9,0 kW

9 - 14 m³

35 x 6 cm

All cross sections of a line are minimum diameters in mm² (Copper line)

Summary of Contents for Thermo-Tec S

Page 1: ...1 D MADE IN GERMANY IP x4 Thermo Tec S Druck Nr 29343829en 28 12 GB Assembly and operating instruction...

Page 2: ...otes 4 Electrical connection 5 Example of a properly connected sauna system 6 Installation 7 Technical data 7 Minimum clearances 7 Sauna stones 9 Maintenance and care 9 Service Address 11 Guarantee 11...

Page 3: ...pped the goods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Please...

Page 4: ...resin untreatedmaterials e g spruce Only a sauna heater with the appropriate power output may be installed in the sau na cabin Please provide air intake and vent ope nings in each sauna cabin The air...

Page 5: ...that the vertical clearance be tween the sauna heater upper edge and the sauna ceiling is maintained Please see also the dimensions diagram for the clearance between the lower edge of the sauna heater...

Page 6: ...y reasons power ca bles may not be laid visibly on the interior walls of the cabin Most sauna cabins have empty ducts fitted into the wall element with the air intake If no empty ducts are available i...

Page 7: ...1500W 9 kW Capacity acc DIN Electrical Connection Fuse control unit in A For cabin size Minimum dimensions of air intake and exhaust vents Connecting cable main control unit in mm Connecting cable con...

Page 8: ...5 4 ea particle board screws 1 set of sauna stones separately in cloth bag The sauna heating unit is intended only for a supply voltage of 400 V AC 3N The minimum height of the sauna cabin must be 1...

Page 9: ...Illust 4 4 Hook the sauna heating unit into the wall mounting using the mounting slots on the rear wall and place against the spacer Illust 7 Terminal box spacer Illust 4 Anschlussklemme Lock nut Cab...

Page 10: ...tones will re heat suffici ently again Never add more essences or volatile oils than advised on the pa ckaging Never use alcohol or un diluted concentrates Caution Fire hazard All sauna heating units...

Page 11: ...ical units will be protected by this ELCB Under current manufacturing technology it is not reasonable to use heating elements for sau na heaters which do not collect moisture from the surrounding air...

Page 12: ...nd model name with detailed description of the fault This guarantee covers defective parts and la bour but not the defects caused by wear and tear In case of complaint please return the equip ment in...

Page 13: ...dual case and try for immedi ate and customer friend ly solution For economic returns wi thin Germany you will get an RMA number from the manufacturer All returns have to be in the original packing of...

Reviews: