Installation Instructions

Model LFWLT450, Class 1 Series AC-DC Power Supply

Additional application information is available from the EOS web site at www.eospower.com

EOS Power India Pvt. Ltd.

Unit # 57, SDF II, SEEPZ, Andheri (East); Mumbai 400 096, India

Phone: +91 22 67744000

ECO NO: 4EM-13-XXX

Page 1 of 7

CEL-22-LF0000000XXXX

AC INPUT

:

100-240 VAC, 6.2 A

47-63 Hz

SAFETY
APPROVALS:

EN60950-1, IEC60950-1 (ed. 2);am1;am2,

UL 60950 (ed.2), CSA C22.2 No.60950-

1(ed.2),Class1 SELV

(Input selection is automatic; no manual change is required)

DC OUTPUT

:

Model Number

Voltage

Max. Load

(Convection)

Min. Load
(420 LFM)

Min. Load

LFWLT450-1000

V1=5V

31.0A

55.0A

0.0A

LFWLT450-1000-I

V1=5V

31.0A

55.0A

0.0A

LFWLT450-1000-T

V1=5V

31.0A

55.0A

0.0A

LFWLT450-1000-I-T

V1=5V

31.0A

55.0A

0.0A

LFWLT450-1000-S

V1=5V

31.0A

55.0A

0.0A

LFWLT450-1000-I-S

V1=5V

31.0A

55.0A

0.0A

LFWLT450-1001

V1=12V

20.83A

37.5A

0.0A

LFWLT450-1001-I

V1=12V

20.83A

37.5A

0.0A

LFWLT450-1001-T

V1=12V

20.83A

37.5A

0.0A

LFWLT450-1001-I-T

V1=12V

20.83A

37.5A

0.0A

LFWLT450-1001-S

V1=12V

20.83A

37.5A

0.0A

LFWLT450-1001-I-S

V1=12V

20.83A

37.5A

0.0A

LFWLT450-1002

V1=15V

16.66A

30.0A

0.0A

LFWLT450-1002-I

V1=15V

16.66A

30.0A

0.0A

LFWLT450-1002-T

V1=15V

16.66A

30.0A

0.0A

LFWLT450-1002-I-T

V1=15V

16.66A

30.0A

0.0A

LFWLT450-1002-S

V1=15V

16.66A

30.0A

0.0A

LFWLT450-1002-I-S

V1=15V

16.66A

30.0A

0.0A

LFWLT450-1003

V1=24V

12.30A

18.75A

0.0A

LFWLT450-1003-I

V1=24V

12.30A

18.75A

0.0A

LFWLT450-1003-T

V1=24V

12.30A

18.75A

0.0A

LFWLT450-1003-I-T

V1=24V

12.30A

18.75A

0.0A

LFWLT450-1003-S

V1=24V

12.30A

18.75A

0.0A

LFWLT450-1003-I-S

V1=24V

12.30A

18.75A

0.0A

LFWLT450-1004

V1=48V

6.25A

9.37A

0.0A

LFWLT450-1004-I

V1=48V

6.25A

9.37A

0.0A

LFWLT450-1004-T

V1=48V

6.25A

9.37A

0.0A

LFWLT450-1004-I-T

V1=48V

6.25A

9.37A

0.0A

LFWLT450-1004-S

V1=48V

6.25A

9.37A

0.0A

LFWLT450-1004-I-S

V1=48V

6.25A

9.37A

0.0A

LFWLT450-1005

V1=30V

10.0A

15.0A

0.0A

LFWLT450-1005-I

V1=30V

10.0A

15.0A

0.0A

LFWLT450-1005-T

V1=30V

10.0A

15.0A

0.0A

LFWLT450-1005-I-T

V1=30V

10.0A

15.0A

0.0A

LFWLT450-1005-S

V1=30V

10.0A

15.0A

0.0A

LFWLT450-1005-I-S

V1=30V

10.0A

15.0A

0.0A

– CAUTIONS & NOTES –

CAUTION:

This component level power supply is intended exclusively for installation within other equipment by an
industrial assembly operation or by professional installers. This is a Class I power supply; the unit
must be properly connected to earth ground in end use.

A component power supply should be

installed in end-use equipment according to the requirements of the safety standard used for that
equipment. This power supply is not designed to be operated outside of an enclosure which provides
a means of mechanical, electrical, and fire protection. To maintain SELV requirements, the outputs
should not be connected together in any manner which causes the total output voltage to exceed 60
VDC.

WARNING:

This is a Class A product. In a domestic environment this product may cause radio interference in which

case the user may be required to take adequate measures.

PROTECTIVE EARTHING:

Summary of Contents for LFWLT450

Page 1: ... V1 24V 12 30A 18 75A 0 0A LFWLT450 1003 T V1 24V 12 30A 18 75A 0 0A LFWLT450 1003 I T V1 24V 12 30A 18 75A 0 0A LFWLT450 1003 S V1 24V 12 30A 18 75A 0 0A LFWLT450 1003 I S V1 24V 12 30A 18 75A 0 0A LFWLT450 1004 V1 48V 6 25A 9 37A 0 0A LFWLT450 1004 I V1 48V 6 25A 9 37A 0 0A LFWLT450 1004 T V1 48V 6 25A 9 37A 0 0A LFWLT450 1004 I T V1 48V 6 25A 9 37A 0 0A LFWLT450 1004 S V1 48V 6 25A 9 37A 0 0A L...

Page 2: ...XXX Page 2 of 7 CEL 22 LF0000000XXXX These products are Class 1 and must therefore be reliably earthed and professionally installed in accordance with the prevailing electrical wiring regulations ENVIRONMENTAL CONDITIONS Transportation Storage Operation Ambient Temperature Range 40 C to 85 C Ambient Temperature Range 0 C to 50 C Relative Humidity Range Relative Humidity Range 5 to 95 RH Non Conden...

Page 3: ...lies to defects in materials and workmanship that result in non performance to published specifications EOS Power assumes no liabilities for consequential damages of any kind through the use or misuse of its products by any user No other obligations are expressed or implied Please note that the specifications terms and conditions stated are subject to change without notice NUCLEAR AND MEDICAL APPL...

Page 4: ...C DC Power Supply Additional application information is available from the EOS web site at www eospower com EOS Power India Pvt Ltd Unit 57 SDF II SEEPZ Andheri East Mumbai 400 096 India Phone 91 22 67744000 ECO NO 4EM 13 XXX Page 4 of 7 CEL 22 LF0000000XXXX ...

Page 5: ...C DC Power Supply Additional application information is available from the EOS web site at www eospower com EOS Power India Pvt Ltd Unit 57 SDF II SEEPZ Andheri East Mumbai 400 096 India Phone 91 22 67744000 ECO NO 4EM 13 XXX Page 5 of 7 CEL 22 LF0000000XXXX ...

Page 6: ...com EOS Power India Pvt Ltd Unit 57 SDF II SEEPZ Andheri East Mumbai 400 096 India Phone 91 22 67744000 ECO NO 4EM 13 XXX Page 6 of 7 CEL 22 LF0000000XXXX PIN ALLOCATION Pin Name Description Input J1 J1 1 Line AC Input Line J1 3 Neutral AC Input Neutral J1 5 Earth AC Input Earth Output J2 Pin 1 V1 V1 Main Output Pin 2 RTN Main Output Return Signal J3 J3 1 NC NC ...

Page 7: ... 7 of 7 CEL 22 LF0000000XXXX Connector Mating Parts Molex or equivalent J3 2 PF OK PF OK J3 3 PG Power Good J3 4 DC RTN DC Return J3 5 5Vstby 5 Standby output J3 6 VE Remote sense VE Remote sense J3 7 VE Remote sense VE Remote sense J3 8 CS Current sharing J3 9 DC Return DC Return J3 10 Remote ON OFF Remote ON OFF FAN Output J4 J4 1 VE VE J4 2 VE VE CONNECTOR HOUSING CRIMP TERMINAL WIRE GAUGE J1 1...

Reviews: