Page 1: ...INNOVATIVE S AU NA TECH NO LO G Y MADE IN GERMANY IP x4 GB Finnrock Druck Nr 29344535en 45 15 Installation and operation manual Sauna heater...
Page 2: ...lectrical connection example 7 Internal wiring diagram 7 Technical data 8 Installation of the Finnrock heater 9 Minimum clearances 9 Sauna rocks 10 Maintenance and care 10 Advice for electrical instal...
Page 3: ...pped the goods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Please...
Page 4: ...resin untreatedmaterials e g spruce Only a sauna heater with the appropriate power output may be installed in the sau na cabin Please provide air intake and vent ope nings in each sauna cabin The air...
Page 5: ...hat the vertical clearance be tween the sauna heater upper edge and the sauna ceiling is maintained Please see also the dimensions diagram for the clearance between the lower edge of the sauna heater...
Page 6: ...hat for safety reasons power ca bles may not be laid visibly on the interior walls of the cabin Most sauna cabins have empty ducts fitted into the wall element with the air intake If no empty ducts ar...
Page 7: ...ier de commande Saunaheizger t Sauna heater Po le de sauna 5 5 Netz Mains R seau 7 5 9 0 kW 12 kW L1 L2 L3 N Sensor Limiter S1 LSG U V W WB WM N 400 V AC 3N 4 3 2 1 Sensor 4 3 2 1 U V W N L1 L2 L3 N S...
Page 8: ...ion LSG unit heater 94 5663 7 5 kW 3 x 16 A 5 x 2 5 mm 5 x 1 5 mm 94 5654 9 0 kW 94 5664 12 0 kW 3 x 16 A 5 x 2 5 mm 4 x 1 5 mm 5 x 1 5 mm All cross sections of connection cables are minimum diameters...
Page 9: ...ng hand ling as the inner parts may have sharp edges Make sure that the heater stands reliably on all four feet Do not load the rocks until the heater is at its final position Make sure to observe the...
Page 10: ...stones will re heat suffici ently again Never add more essences or volatile oils than advised on the packaging Never use alcohol or undiluted concentrates Cau tion Fire hazard All sauna heating units...
Page 11: ...l units will be protected by this ELCB Under current manufacturing technology it is not reasonable to use heating elements for sau na heaters which do not collect moisture from the surrounding air It...
Page 12: ...el name with detailed description of the fault This guarantee covers defective parts and labour but not the defects caused by wear and tear In case of complaint please return the equip ment in its ori...
Page 13: ...p ping of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall accept no liability for damage incu...