48
Installation Instructions - InfraStyle / InfraStyle i
Installation
EN
8
Place the bottom piece in the prepared wall cut-out.
Observe the sticker on the housing (oben/up).
When fixing the unit to the wall, ensure that the bottom of the unit is
aligned properly. The side with the slots for the removal tool must be
facing to the right.
9
Slide the clips as far out as they will go and tighten the screws clockwise.
The housing must sit firmly in the wall cut-out.
10
Mount the voltage regulator outside of the cabin.
The cable is approx. 3 m long. It may not be taught.
InfraStyle i: Inserting the S-Bus and voltage regulator line
1
Insert the control line with the RJ10 plug into the circuit board.
The control line's RJ10 plug is inserted into the control panel. The
RJ14 plug is inserted into the relay box.
2
NOTICE Do not tilt the plug when inserting or removing it. The circuit
board’s jack must not be damaged or broken off.
The jack and/or the circuit board cannot be repaired or replaced.
Insert the voltage regulator's connecting cable.