EOC GUVX-T1XGS7.1-L Manual Download Page 1

Electro Optical Components, Inc.

5464 Skylane Boulevard, Suite D, Santa Rosa, CA 95403

Toll Free: 855-EOC-6300

www.eoc-inc.com

 

 |   

 [email protected]

Genicom Co., Ltd.                                                                                             2020-rev.1-SA.HAN

Manual
Radiometer 7.1

GUVX-T1XGS7.1-L    

GUVX-T1XGS7.1-LA9

Genicom Co., Ltd.                                                                                             2020-rev.1-SA.HAN

1. MG-07.1 [GUVX-T1XGS7.1-L] Manual _ English 

·························Page 2 ~ 11

3. MG-07.1 [GUVX-T1XGS7.1-LA9] Manual _ English 

·····················Page 12 ~ 21

Contents

Page 1

Summary of Contents for GUVX-T1XGS7.1-L

Page 1: ...855 EOC 6300 www eoc inc com info eoc inc com Genicom Co Ltd 2020 rev 1 SA HAN Manual Radiometer 7 1 GUVX T1XGS7 1 L GUVX T1XGS7 1 LA9 Genicom Co Ltd 2020 rev 1 SA HAN 1 MG 07 1 GUVX T1XGS7 1 L Manual...

Page 2: ...Method 5 1 Battery check 5 2 Precautions for battery replacement 5 3 Power ON or OFF 5 4 Function button 5 5 Reset cumulative light intensity Dose or maximum light intensity Max power 5 6 Measuring th...

Page 3: ...e Max 12 min Max Power mW cm2 Index UVI Conversion rate 3 Readings Sec Display 4 0 Digit LCD LCD size 17 x 44 Operation temperature 0 60 Operation humidity RH 10 85 Accuracy 10 NIST Traceable Indicato...

Page 4: ...duct Information Sticker Battery Cover This is a 9V battery cover Open the battery cover to insert and replace the battery Inside of Battery Cover Serial number can be checked inside of battery cover...

Page 5: ...evice ON OFF 5 4 Function button If push the function button the function display will change in order ex Absolute power Dose Max power Absolute power Push the power button for 3 seconds Power ON Abso...

Page 6: ...the measuring instrument When the measured value differs depending on the light source Please check page 5 relative response curve Even if included in the measurement range the output value may vary d...

Page 7: ...d 5 1 Battery check 5 2 Precautions for battery replacement 5 3 Sensor probe connection 5 4 Power ON or OFF 5 5 Function button 5 6 Reset cumulative light intensity Dose or maximum light intensity Max...

Page 8: ...me Max 12 min Max Power mW cm2 Index UVI Conversion rate 3 Readings Sec Display 4 0 Digit LCD LCD size 17 x 44 Operation temperature 0 60 Operation humidity RH 10 85 Accuracy 10 NIST Traceable Indicat...

Page 9: ...16 In the case of index meter Genicom Co Ltd 2020 rev 1 SA HAN Product Information Sticker Battery Cover This is a 9V battery cover Open the battery cover to insert and replace the battery Inside of B...

Page 10: ...e sensor probe to indicator If you connect it in the right direction it will be fixed with a click sound Page 19 5 4 Power ON or OFF If you push the power button for 3 seconds translate the device ON...

Page 11: ...below 7 V the power is not turned on or the batt message is output When the screen is dimmed Please replace the battery Depending on the voltage consumption of the battery the screen may become blurre...