background image

MEV SPIDER

VENTILATION UNIT INSTALLATION GUIDE

AFTER INSTALLATION THE END USER SHOULD 

KEEP THIS GUIDE FOR FUTURE REFERENCE

DO NOT THROW AWAY

Summary of Contents for MEV SPIDER

Page 1: ...MEV SPIDER VENTILATION UNIT INSTALLATION GUIDE AFTER INSTALLATION THE END USER SHOULD KEEP THIS GUIDE FOR FUTURE REFERENCE DO NOT THROW AWAY...

Page 2: ...ations in relation to open flues from appliances e g boilers You must ensure the external supply grilles are positioned away from open flues to avoid drawing harmful gases into the property Consult yo...

Page 3: ...ting cable If the power cable becomes damaged it must be replaced by EnviroVent an authorised service agent for your region country or a similarly qualified person in order to avoid a hazard Do not re...

Page 4: ...UNIT CALL US ON 3 Diagrams Overall unit dimensions and minimum area required for access maintenance 64 640 0 440 440 357 357 557 557 698 698 19 198 8 The extract spigots are compatible with 100mm duc...

Page 5: ...r similar The black switch live core of the mains cable can be wired to a switch input such as the supplied boost switch or a light switch When the switch is turned on the boost function is engaged Wh...

Page 6: ...tiple locations The unit is suitable for houses apartments and communal properties with a kitchen and up to 6 additional wet rooms The unit is capable of delivering a maximum airflow of 129l s 465m3 h...

Page 7: ...foam pads 4 x Rubber sleeves 1 x Wireless remote control MEVS W units only 1 x Wired boost switch MEVS H units only Pre installation checklist Does the unit fit in the space where it will be installed...

Page 8: ...guide to mark the 4 fixing holes Then remove the unit and drill the fixings holes and insert a plasterboard plug into each hole 3 Insert a rubber sleeve into each of the four fixing points at the corn...

Page 9: ...s with a light tap and discard them It may be necessary to remove excess material with the knife 6 If a spigot hole is removed in error use the spare blank provided to cover the hole and glue it in pl...

Page 10: ...duct between the extract valves and the MEV unit 9 10 11 Extract termination Extract 1 Extract 2 Extract 3 Ductwork should be fitted in accordance with the Domestic Ventilation Compliance Guide and fo...

Page 11: ...t to the local isolator as per the wiring diagram on page 4 and in accordance with the local wiring regulations When the power is turned on air will begin flowing through the system after a few second...

Page 12: ...lation Compliance Guide for England and Wales For MEV commissioning guidance in other countries please refer to the relevant local Building Regulations for that country Determine the required ventilat...

Page 13: ...sure Then lock the valves in position Press the SET button once to move on to the extract trickle flow rate LED s A C D will light and LED B will flash indicating that the extract trickle flow rate is...

Page 14: ...t switch can be pressed to manually activate boost mode Turn the switch off to deactivate the boost mode Wireless Remote Control MEVS W only To manually activate the boost function Press the button on...

Page 15: ...nce within the 20 seconds and the remote control will pair to the unit If the pairing has succeeded the green LED will light up Replacing the remote control battery Undo the two screws and remove the...

Page 16: ...N 15 Technical specification Extract spigot diameter 100mm External spigot diameter 125mm Maximum air flow rate 129l s 465m3 h Maximum power consumption 70W Electrical Supply 230V Single Phase 50Hz In...

Page 17: ...alves and vents are connected mechanically fixed and sealed The unit is securely fixed with adequate space left for maintenance All major building works have been completed prior to commissioning Air...

Page 18: ...screws and remove the lid as in installation step 13 Now undo the motor plate screws and lift the motor plate assembly backwards then out of the unit The power cable will remain attached between the...

Page 19: ...led by a third party it is covered by a parts only warranty If you detect a fault and the product has been installed in accordance to the fitting wiring instructions relevant guidance documents and by...

Page 20: ...and appearance without notice We want to hear from you Your feedback is important to us as we strive to improve our products services and overall customer experience Please email us to help us serve...

Reviews: