Section 1 -

 

Warranty Information 

 

LIMITED WARRANTY 

The Environmental Express IAQ 15 Connect is warranted against defects in materials and workmanship when 

used in accordance with applicable instructions, for a period of one (1) year from the date of shipment. This 

warranty extends to parts, labor, and any approved transportation costs. This warranty applies only to damage 

or failure caused by normal use. The warranty is limited to product repair. If Environmental Express is unable to 

repair the IAQ 15 Connect, the customer may, at his or her option, receive a replacement unit or a full refund. 

In no event shall Environmental Express have any obligation to make repairs, replacements, or corrections 

required, in whole or in part, as the result of (i) normal wear and tear, (ii) accident, disaster or event of force 

majeure, (iii) abuse, neglect, misuse, fault, or negligence of or by customer, (iv) use of the product in a manner 

for which it was not designed, (v) causes external to the product such as, but not limited to, power failure or 

electrical power surges, (vi) improper storage and handling of the product, (vii) use of the product in 

combination with equipment or software not supplied by Environmental Express, (viii) ordinary maintenance, 

(ix) alterations, repairs or installations that have not been performed by Environmental Express or its authorized 

representative or (x) failure to maintain product in accordance with Environmental Express’ written instructions. 

Environmental Express makes no other warranty, expressed or implied for this product with respect to 

merchantability, fitness for a particular use or any other matter and expressly disclaims all other warranties. 

Environmental Express is not liable for any consequential, special, indirect, or compensatory damages arising 

from use of, or in conjunction with this product. The maximum liability of Environmental Express (whether by 

reason of breach of contract, tort, indemnification, or otherwise provided herein) shall be the invoice price of 

this product. 

 

REPAIR POLICIES

 

If it should become necessary to return the IAQ 15 Connect pump for service, please call Environmental Express 

at 1-352-854-8080 for a return authorization number and return instructions. Please have the unit serial number 

and a description of the problem handy. All units must be complete with the pump, case, charger, and flow 

indicator for a complete evaluation. Units returned without all of these items cannot be thoroughly evaluated by 

our service department. The sender is responsible for shipping charges, freight, insurance and proper packaging 

to prevent damage in transit. A return authorization number must be issued prior to shipment and must be 

marked on your shipment.  

 

Under Warranty Repair

 

If the IAQ 15 Connect should fail to operate as warranted within the warranty period (one year from date of 

shipment), Environmental Express will repair it and ship it back to the customer at Environmental Express’ 

expense. The remainder of the warranty period will be honored from the original ship date. Environmental 

Express will bear the cost of ground transportation both to and from the customer’s location, and bear the cost 

of any parts, labor, and cleanup required. 

If, however, it is determined that the damage to the IAQ 15 Connect was caused by negligence or improper use 

or by another excluded cause as set forth above, this warranty will not apply. The warranty is also void if the 

system is used beyond its intended purpose or in the event of any unauthorized repair. In such cases, reasonable 

and customary repair charges will apply. Repair charges will be quoted prior to work being done. 

Summary of Contents for IAQ 15 Connect

Page 1: ...T 1 800 343 5319 1 843 881 6560 W environmentalexpress com LA03115 Rev 1 IAQ 15 Connect Operating Instruction Manual...

Page 2: ...ncluded 5 Section 5 Physical Description 6 Section 6 Prior to Operation 7 Section 7 Calibration 7 Section 8 Sampling Modes 8 Section 9 Retrieval of Event Records with App 10 Section 10 Battery Status...

Page 3: ...ble for any consequential special indirect or compensatory damages arising from use of or in conjunction with this product The maximum liability of Environmental Express whether by reason of breach of...

Page 4: ...S s Operation is subject to the following two conditions 1 This device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation o...

Page 5: ...in a manner for which it is not intended Technical Specifications Flow rate 15 LPM Accuracy 5 Housing PC ABS plastic Battery rechargeable nickel metal hydride NiMH 9 6 V 2500 mAh Run time 99 five min...

Page 6: ...ner 2 LCD 3 F1 button increase 4 F2 button enter 5 F3 button decrease 6 Bluetooth button 7 Power On Off and Wake up button 8 AC charger input jack Bottom View of Pump 1 Battery pack Battery cover 2 Gr...

Page 7: ...very day of use A flow indicator for Air O Cell cassettes is supplied with the pump for ease of calibration You may also calibrate the pump using an optional TSI 4046 Primary Calibrator with attachmen...

Page 8: ...tures a choice of 3 different sampling modes We strongly recommend that the sampling mode is chosen after calibration is complete Quick Sample This mode allows easy sampling with the most commonly use...

Page 9: ...llowed by one cycle off time Enter the Cycle Run Time run time will be the same for all run cycles Enter the Cycle Off Time off time will be the same for all off cycles 5 Press F1 button Run Time of C...

Page 10: ...10 environmentalexpress com 4 Once complete check mark will appear between the IAQ 15 Connect and mobile device with message stating Bluetooth Data Transfer Success...

Page 11: ...be displayed on the home screen Previous sample may be continued or a new sample may be started To charge the battery pack plug in the AC charger on the right side of the pump The yellow LED will fla...

Page 12: ...Section 13 Maintenance Proper care and maintenance of your IAQ 15 Connect pump is essential for a long operational life It is a delicate electronic device and should be treated accordingly Rough and a...

Page 13: ...art Heavy duty tripod sampling stand ZA0043 Remote extension tubing 5 ft ZBP 310 Calibration kit with TSI 4046 Primary Calibrator ZBP 200 CAL Flow indicator for calibrating Via Cell cassettes ZBP 305...

Reviews: