Section 12 -

 

Cautions and Warnings 

 

 

 

Only the battery pack should be opened on the pump using the molded battery cover key supplied.  

Do not remove the screws and open the bottom enclosure from the top enclosure.  

 

Always follow basic safety precautions when using this product to reduce the risk of injury, fire, or 

electric shock.  

 

Batteries may explode or leak and cause burn injury if disassembled from battery pack.  

 

Use only the charger and battery supplied with the IAQ 15 Connect pump. Using a different battery or 

charger can damage the pump or cause injury from explosion, and may void warranty. 

 

Do not submerge the pump or subject the pump to any liquids. 

 

Do not block the vent holes under the unit.  

 

Section 13 -

 

Maintenance 

 

Proper care and maintenance of your IAQ 15 Connect pump is essential for a long operational life. It is a delicate 

electronic device and should be treated accordingly. Rough and abusive use and/or accidental impacts may 

damage the unit. Environmental Express offers the following guidelines in caring for your equipment: 

 

Keep the unit clean and free of dust and dirt. It may be wiped down with a clean dry cloth.  

 

Keep the battery charged. Charge periodically when not used for a prolonged amount of time or leave 

plugged in for a continuous trickle charge.  

 

Always store the unit in its case for proper protection.  

 

Do not ship the unit using the carrying case as the shipping container. The case is not designed to be a 

shipping container and damage may occur.  

 

Do not attempt to oil the motor. The motor is designed to be maintenance free.  

 

Do not store the unit in extreme heat for any extended period of time. 

 

 

Summary of Contents for IAQ 15 Connect

Page 1: ...T 1 800 343 5319 1 843 881 6560 W environmentalexpress com LA03115 Rev 1 IAQ 15 Connect Operating Instruction Manual...

Page 2: ...ncluded 5 Section 5 Physical Description 6 Section 6 Prior to Operation 7 Section 7 Calibration 7 Section 8 Sampling Modes 8 Section 9 Retrieval of Event Records with App 10 Section 10 Battery Status...

Page 3: ...ble for any consequential special indirect or compensatory damages arising from use of or in conjunction with this product The maximum liability of Environmental Express whether by reason of breach of...

Page 4: ...S s Operation is subject to the following two conditions 1 This device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation o...

Page 5: ...in a manner for which it is not intended Technical Specifications Flow rate 15 LPM Accuracy 5 Housing PC ABS plastic Battery rechargeable nickel metal hydride NiMH 9 6 V 2500 mAh Run time 99 five min...

Page 6: ...ner 2 LCD 3 F1 button increase 4 F2 button enter 5 F3 button decrease 6 Bluetooth button 7 Power On Off and Wake up button 8 AC charger input jack Bottom View of Pump 1 Battery pack Battery cover 2 Gr...

Page 7: ...very day of use A flow indicator for Air O Cell cassettes is supplied with the pump for ease of calibration You may also calibrate the pump using an optional TSI 4046 Primary Calibrator with attachmen...

Page 8: ...tures a choice of 3 different sampling modes We strongly recommend that the sampling mode is chosen after calibration is complete Quick Sample This mode allows easy sampling with the most commonly use...

Page 9: ...llowed by one cycle off time Enter the Cycle Run Time run time will be the same for all run cycles Enter the Cycle Off Time off time will be the same for all off cycles 5 Press F1 button Run Time of C...

Page 10: ...10 environmentalexpress com 4 Once complete check mark will appear between the IAQ 15 Connect and mobile device with message stating Bluetooth Data Transfer Success...

Page 11: ...be displayed on the home screen Previous sample may be continued or a new sample may be started To charge the battery pack plug in the AC charger on the right side of the pump The yellow LED will fla...

Page 12: ...Section 13 Maintenance Proper care and maintenance of your IAQ 15 Connect pump is essential for a long operational life It is a delicate electronic device and should be treated accordingly Rough and a...

Page 13: ...art Heavy duty tripod sampling stand ZA0043 Remote extension tubing 5 ft ZBP 310 Calibration kit with TSI 4046 Primary Calibrator ZBP 200 CAL Flow indicator for calibrating Via Cell cassettes ZBP 305...

Reviews: