9. Remove the drain line (9) from the bottom of the humidifier.
If applicable, flex it to loosen any mineral deposits or
blockage. Then flush it with water under pressure. If it does
not properly clear, replace it. Slip drain line back onto
the drain fitting. Make sure the drain line has a constant
downward slope and is not flattened or blocked.
10. Turn on the water supply. Return integral bypass damper
to appropriate position.
11. Check system operation:
Manual Humidifier Control:
With the HVAC blower
operating, turn up Humidifier Control and check system
operation.
Digital Humidifier Control:
(Automatic or Manual mode)
Check system operation and reset Change Water Panel
indicator by setting the knob to “Test/Reset”. With HVAC
blower operating and HVAC calling for heat, humidifier will
operate for one minute.
DO NOT LEAVE IN TEST MODE
AS HUMIDIFIER WILL NOT OPERATE.
12. Set Humidifier Control to its original position.
LIMITED WARRANTY
Your EnviroAire IAQ humidifier unit is expressly warranted
for five (5) years from date of installation to be free from
defects in materials or workmanship except, however, for the
disposable water panel which will have to be replaced from
time to time depending upon the amount of use.
EnviroAire IAQ’s exclusive obligation under this warranty
shall be to supply, without charge, a replacement for any
part of the humidifier which is found to be defective within
such five (5) year period and which is returned not later
than thirty (30) days after said five (5) year period by you to
your original supplier, together with the model number and
installation date of the humidifier.
THIS WARRANTY SHALL NOT OBLIGATE ENVIROAIRE
IAQ FOR ANY LABOR COSTS AND SHALL NOT APPLY TO
DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED
BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN
THE HUMIDIFIER ITSELF.
IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED
IN DURATION TO THE AFORESAID FIVE YEAR PERIOD.
ENVIROAIRE IAQ’S LIABILITY FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES
FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH
OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE
LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED
WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE
TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATING
AND AIR CONDITIONING CONTRACTOR. IF THE
LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A
QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED
WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION.
Some states do not allow limitations on how long an implied
warranty lasts or the exclusion or limitation of incidental or
consequential damages so the above exclusion or limitations
may not apply to you.
This warranty gives you specific legal rights and you may
also have other rights which vary from state to state.
ANNUAL SUMMER SHUTDOWN
Close the bypass damper, which is a part of the humidifier,
with the small damper handle.
Digital Humidifier Control in Automatic Mode (see Figure A):
No adjustment is necessary.
Digital Humidifier Control in Manual Mode (see Figure B):
Set the knob to the “OFF” position.
Manual Humidifier Control (see Figure C): Set the knob to
the “OFF” position.
© 2020 EnviroAire IAQ