10

 

Power Consumption Indicators 

Pixel Triton displays a power consumption graphic 
on the home page of the web interface. 

 

 

 

The  numerical  power  value  underlined  in  the 
image is the sum of the:

 

 

Power consumption of the internal circuits

 

 

Power drawn through the output port when 

a load is connected.

 

Note:

 

 

The tolerance of this displayed value is ±6%.

 

This numerical value is also shown as a percentage 

of power consumed out of the total available for 
each output as shown in the image.

 

 

The maximum power available for each XLR output 
is shown in the table below

 

Product Part 

No.

 

Output 

Voltage

 

Maximum 

Power

 

75020-12

 

12V

 

130 W

 

75020-24

 

24V

 

150 W

 

 

Pixel  Triton  has  a  feature,  which  informs  a  user 

when the power consumed through an output has 
reached  or  exceeded  80%  of  the  allocated  value; 

this  is  shown  both  on  the  web  interface  and 
through LED indicators. 

 

 

All  the  above-mentioned  features  are  aids  for 

users to determine when to inject power using an 
external source. 

 

Once the warning text is displayed, we recommend 
to  power  inject  any  additional  tape  or  dots 

connected; as shown in the images that follow

 

 

 

Note:

 

 

When using an external DC power supply for injection, 
common Ground is recommended to avoid flicker

 

Overloading the device, that is, attempting to draw 
more than the allocated power through an output 

will reduce the lifetime of the device.

 

When  overloaded,  the  device  will  go  to  hiccup 

mode;  where  the  power  supply  in the  device will 
momentarily switch off, then after a second or so 

will  start  up  again.  This  will  continue  until  the 
overload situation has been resolved.

 

Summary of Contents for Pixel Triton

Page 1: ...tion 5 Home 5 Settings 6 Network Stats 6 Update Firmware 6 General Settings Explained 7 Node Name 7 DHCP 7 DMX Protocol 7 Output Settings 7 Pixel Mapping Options 7 Definition of Pixel 7 Pixel Order 7...

Page 2: ...ever plug this unit in to a dimmer pack Ensure proper earth connections Always be sure to mount this unit in an area that will allow proper ventilation Allow about 6 inches 20 cm between this device a...

Page 3: ...et connection Web faders for instant testing of setup LED Status Pixel Triton has 8 LED indicators Power LED Device Activity LED Link and activity LED each ethernet port Output limit indicator for eac...

Page 4: ...hen connected in network daisy chain Only one ethernet source must be used to drive the device at any single time Ensure distance between Triton data output and tape dot data input is not more than 50...

Page 5: ...imal Where byte 2 C8 is 200 in decimal Where byte 3 A8 is 168 in decimal Using the IP address one can access the built in web interface of the Pixel Triton via any modern web browser The web interface...

Page 6: ...ny operating system can be used Either click on the underlined URL displayed in NMU or type the IP address as detected by NMU e g 10 10 2 19 into your web browser to access the web interface The left...

Page 7: ...e controlled Pixel grouping settings Test the device and or tape using faders Reset to factory defaults Reboot device Network Stats The Network page shows statistics for the DMX protocol enabled The i...

Page 8: ...t protocol to be picked Available options Art Net sACN Notes For Art Net Net and Subnet can be specified and should comply with Art Net 3 protocol Output Settings This setting specifies the LED protoc...

Page 9: ...tically assigned subsequent universes to the first one Example 1 If the first universe is assigned 25 the second third and fourth universes will be automatically assigned 26 27 and 28 as shown in the...

Page 10: ...a if the disable fader radio button is selected Reboot Device Reboot button which is under settings pages restarts the unit Reset to Defaults The reset to defaults command can be found under the Setti...

Page 11: ...24 24V 150 W Pixel Triton has a feature which informs a user when the power consumed through an output has reached or exceeded 80 of the allocated value this is shown both on the web interface and th...

Page 12: ...are Note While the firmware is being updated please do not power off the unit please wait until the web interface is processing up to a minute If the web page does not refresh automatically please ope...

Page 13: ...75020 24 24V 6 25 A How to Recover Pixel Triton If the Pixel Triton Crashes Is assigned an IP address that cannot be accessed by the local network or that cannot be discovered NMU can be used to reco...

Page 14: ...Current 10 83A 6 25A Supported Protocols Artnet 1 2 3 sACN Output Protocols WS2811 WS2812 WS2812B WS2813 SK6812 TM1804 TM1812 UCS2903 UCS2904 APA 104 9PDOT 8 16bit Maximum Pixel count output RGBW 512...

Page 15: ...RGB PIXEL TAPE 60 LEDS METER 12V 5M Roll 8PL30 F RGB PIXEL TAPE 30 LEDS METER 5V 5M Roll 8PL60 F RGB PIXEL TAPE 60 LEDS METER 5V 5M Roll 8PL144 2 RGB PIXEL TAPE 144 LEDS METER 5V 2M Roll 8PX60 4 RGBW...

Reviews: