ENTRYPASS N-MINI 2 Wiring Manual Download Page 1

Copyright © Entrypass Corporation 

ENTRYPASS TECHNICAL – WIRING GUIDE 

Version: 1.07 

Last Updated: 23-06-2016 

EP.N-MINI 2 WIRING GUIDE 

Summary of Contents for N-MINI 2

Page 1: ...Copyright Entrypass Corporation ENTRYPASS TECHNICAL WIRING GUIDE Version 1 07 Last Updated 23 06 2016 EP N MINI 2 WIRING GUIDE...

Page 2: ...ct your system installer Your installer is familiar with your system configuration and should be able to answer any of your questions Should you need additional information please call our Technical S...

Page 3: ...ase follow the instruction below Observe precautions while handling the circuit board assembly by using proper grounding straps and handling precautions at all Visually ensure no onboard parts is brok...

Page 4: ...Copyright Entrypass Corporation ENTRYPASS TECHNICAL WIRING GUIDE N MINI 2 Reader N MINI 2 DRB N MINI 2 Description...

Page 5: ...Copyright Entrypass Corporation ENTRYPASS TECHNICAL WIRING GUIDE Heartbeat Indication Tricolor LED CapSense Touch Button with Backlight Color LCD Screen N MINI 2 Description...

Page 6: ...hite RS485 C1 Green RS485 C1 Yellow RS485 C2 Blue RS485 C2 CN2 Color Description Black Jacket Cat 5e cable White Orange White Orange Orange Orange White Green White Green Blue Blue White Blue White Bl...

Page 7: ...ault and Crypto Key reset Selection Jumper Relay 1 LED RS485 COM Chip Dip Switch ON 1 2 3 4 5 PCB Version JP6 Vout2 Supply Voltage Selector 2 Supply Voltage Selector Put the jumper cap at JP5 1 2 to o...

Page 8: ...ally Open NC2 Relay 2 Normally Close CM2 Relay 2 Common NO2 Relay 2 Normally Open ACC AC Fail Monitoring BATT Backup Battery Monitoring IN1 Input 1 IN2 Input 2 GND Ground IN3 Input 3 IN4 Input 4 GND G...

Page 9: ...er RD02 Reader 2 Data 0 Input Reserved RD12 Reader 2 Data 1 Input Reserved GRN2 Reader 2 Green LED Reserved RED2 Reader 2 RED LED Reserved BZR2 Reader 2 Buzzer Reserved TMP2 Reader 2 Tamper Reserved C...

Page 10: ...Copyright Entrypass Corporation ENTRYPASS TECHNICAL WIRING GUIDE ENTRYPASS Power Supply Unit Specification Switching Power Supply 12V DC 3 Amp MINImum Power Supply Unit Specification...

Page 11: ...LD HRT MCU RS485 COMM1 RS485 COMM2 Addressing Dip Switch Relay 1 Relay 2 GND ETH RS232 C1 RS232 C2 Selection Jumper Vout1 Vout2 LED1 LED2 Buzzer 12V Power Supply 12V DC GND Power Supply Ground ETH Pow...

Page 12: ...h is used for setting the unit address of the DRB to match the RDK Each switch is represent by an address the sum of the switch address will be the controller address The number in RED color is the ad...

Page 13: ...002 OFF ON OFF OFF OFF 003 ON ON OFF OFF OFF 004 OFF OFF ON OFF OFF 005 ON OFF ON OFF OFF 006 OFF ON ON OFF OFF 007 ON ON ON OFF OFF 008 OFF OFF OFF ON OFF 009 ON OFF OFF ON OFF 010 OFF ON OFF ON OFF...

Page 14: ...OFF ON 018 OFF ON OFF OFF ON 019 ON ON OFF OFF ON 020 OFF OFF ON OFF ON 021 ON OFF ON OFF ON 022 OFF ON ON OFF ON 023 ON ON ON OFF ON 024 OFF OFF OFF ON ON 025 ON OFF OFF ON ON 026 OFF ON OFF ON ON 02...

Page 15: ...N3 IN4 GND GND GND 12V GND 12V GND Emergency Breakglass Emergency Keyswitch PSU Electro Magnetic Lock or Drop Bolt Connecting the Lock NC Breakglass and Keyswitch Diode 1N4002 must be installed at the...

Page 16: ...GUIDE 12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND 12V GND Electro Strike Lock 12V GND PSU Diode 1N4002 must be installed at the locking devices in order to protect a...

Page 17: ...rypass Corporation ENTRYPASS TECHNICAL WIRING GUIDE Door Sensor Push Button IN1 IN2 GND 12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND GND Connecting the Door Sensor an...

Page 18: ...configure MINI as a READER Mode press F1 123456 01 Enter 01 Enter 05 Enter 1 Enter ESC x3 Vout1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1 C1 C2 C2 Red 12V Black GND Oran...

Page 19: ...TMP2 C1 C1 C2 C2 Red 12V Black GND Green D0 White D1 Green LED Buzzer Tamper Connecting the Reader 3rd Party Reader Put the jumper cap at JP5 1 2 to output 12VDC at Vout1 Put the jumper cap at JP5 2...

Page 20: ...2 RD12 GRN2 RED2 BZR2 TMP2 C1 C1 C2 C2 Red 12V Black GND Green W D0 White W D1 Yellow with Black stripe C2 Blue with white stripe C2 Note Connect to N MINI 2 C2 C2 Black W GND 12V GND EARTH NC1 CM1 NO...

Page 21: ...RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1 C1 C2 C2 Red 12V Black GND Green W D0 White W D1 Yellow C2 Blue C2 Note Connect to NMINI2 C2 C2 Black W GND 12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BA...

Page 22: ...11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1 C1 C2 C2 12V GND EARTH CM1 CM2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND RST COLD HRT MCU RS485 COMM1 RS485 COMM2 Addressing Dip Switch Relay 1 R...

Page 23: ...ICAL WIRING GUIDE CAT 5e Network Cable EntryPass Platform1 Server Access Control System Network Switch N MINI 2 1 N MINI 2 2 N MINI 2 3 N MINI 2 n Connecting to the PC via Network Factory default IP a...

Page 24: ...Vout1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1 C1 C2 C2 12V GND EARTH CM1 CM2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND RST COLD HRT MCU RS485 COMM1 RS485 COMM2 Addressi...

Page 25: ...Vout1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1 C1 C2 C2 12V GND EARTH CM1 CM2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND RST COLD HRT MCU RS485 COMM1 RS485 COMM2 Addressi...

Page 26: ...orming Crypto Key reset Vout1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1 C1 C2 C2 12V GND EARTH CM1 CM2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND RST COLD HRT MCU RS485 CO...

Page 27: ...tch 12V GND PG BAT BS VS CAT 5 Network Cable Power Supply Mini as Reader Network Switch N MINI 2 Vout1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1 C1 C2 C2 12V GND EARTH N...

Page 28: ...1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1 C1 C2 C2 12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND RST COLD HRT MCU RS485 COMM1 RS485 CO...

Page 29: ...cy Keyswitch 12V GND PG BAT BS VS CAT 5 Network Cable Power Supply Network Switch N MINI 2 Vout1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1 C1 C2 C2 12V GND EARTH NC1 CM1...

Page 30: ...TECHNICAL WIRING GUIDE Company Name Display Time or Logo Previous Tab Menu Next Tab Menu Calendar Time Use the or key to access any Tab Menu Quick Function Time Attendance Diagnostic and press OK to a...

Page 31: ...yright Entrypass Corporation ENTRYPASS TECHNICAL WIRING GUIDE Press Menu to access Main Menu Default Password 123456 Use the or key to choose the Menu Items and press OK to select N MINI 2 User Interf...

Page 32: ...Copyright Entrypass Corporation ENTRYPASS TECHNICAL WIRING GUIDE Use the or key to perform Up and Down press OK to select press Menu to back exit N MINI 2 User Interface...

Page 33: ...king Idle Sleep Mode Green Static Valid Action e g Valid Card Entry Red Static Invalid Action e g Door Force Open Red Blinking System Error e g No Physical Network Conn Please check the system error i...

Page 34: ...ing IP Address Subnet Mask Gateway Port Listen Port Transmit Server IP Ethernet Speed Quit Date Setting Time Setting Command Reset Door Data Format Memory Factory Default Reset AES Quit Quit Database...

Page 35: ...latform1 Access Control System please make sure all the wiring connection is correct On the N MINI 2 RDK please make sure the following setting has been done Factory Default IP Address Subnet Mask Gat...

Page 36: ...new admin pin 6 digits Key in new pin again 6 digits MENU X3 Format Memory Enter programming mode System Icon OK 06 OK 02 OK 1 1 During formatting long beep sound will be heard MENU X3 Factory Default...

Page 37: ...ng mode System Icon OK 02 OK 04 OK 01 OK Key in the new door pin 6 digits Menu 05 OK 01 OK 001 MENU X4 Gateway Enter programming mode System Icon OK 03 OK 03 OK Key in the new Gateway MENU X3 Server I...

Page 38: ...MENU X4 Open Time Enter programming mode System Icon OK 02 OK 09 OK Key in the new open time 00 99 MENU X3 Release Time Enter programming mode System Icon OK 02 OK 08 OK Key in the new release time 0...

Page 39: ...ode DB Icon OK 01 OK 05 OK Flash all the cards to be deleted card by card MENU X4 DRB Version Enter programming mode Info Icon OK 02 OK MENU X3 Quick Install Enter programming mode DB Icon OK 01 OK 04...

Page 40: ...485 800m 2400 ft 22 AWG 2 Pairs Shielded Twisted Pair DRB to Reader Wiegand 30m 100 ft 22 AWG 2 Pairs Shielded Twisted Pair NMINI2 to Power Supply Power 30m 100 ft 18 AWG 1 Pair DRB to Electro Magneti...