14
System Power On and Power Off
Power Off the System
Remove AC power from the system any time service is being performed.
1.
Wait until all production tasks are complete.
2.
Select the Windows Shutdown command, and wait for the Controller PC to shut
down.
3.
Turn the E-Stop switch counterclockwise to OFF. The word OFF is then visible
in the dial cutout. This removes power from the following:
All modules
The system fans
Modules that are supplied by additional power cord inlets
4.
If you are performing service on the PB8500 system:
a.
Unplug the power cord(s) from the AC power source.
b.
Capture the female end of the AC cord into a certified lock-out device,
such as the sample shown here, and lock it with a padlock.
Each person servicing the system should have their own
personal lock.
Caution: Never remove someone else’s lock from a lockout.
Summary of Contents for PB8500
Page 1: ...October 2021 528302 001 Rev A Operator s Guide Datacard Passport Issuance System PB8500...
Page 6: ...3 Multi Book Chip Module 59 Laser 450G Module 60 Secure Overlay 61 Buffer Closer QA Module 62...
Page 22: ...16 System Power On and Power Off...
Page 28: ...22 Load Supplies...
Page 42: ...36 Production...
Page 62: ...56 Preventive Maintenance...
Page 70: ...64 Troubleshooting...