Turns-Ratio Calibration
The Turns Ratio calibration defines the turns-ratio of the transformer connected to the iPAK2v2. The turns ratio is used
to calculate the secondary current from the measured primary current.
The calibration procedure for setting the turns-
ratio using NetFlash™ is:
1)
Determine the Turns Ratio from the welding transformer data sheet or transformer product label
2)
Connect the computer to the control via an Ethernet cable
3)
Turn ON the iPAK2v2 weld control
4)
Open the
NetFlash™ software application on a computer and connect to the target control
5)
Load the parameters from the target control by clicking the
Load From Control
Icon
6)
Navigate to the
Calibrate Current
tab
7)
Check the
Turns Ratio
checkbox
8)
Enter the transformer Turns-Ratio into the
Turns-Ratio
field and press
Enter
or
Tab
to push the
change to the control