Step by step procedure
The recommended height for fixing of the terminal is 1.40m (top of the product).
For an optimal use the terminal must be installed in an area where the
lighting conditions are controlled. Avoid direct exposure of the sensor to
the sun light.
Power supply from electrical source shall be switched off before starting
the installation.
The strength of the attachment depends on the solidity of the wall on
which the terminal is mounted.
To ensure water tightness, the pre-wired back door has to be attached to
the product with the 4 screws (refer to corresponding picture for process).
Drilling the mounting holes
Figure 7: Drilling template
60,1mm
Scale 1.0
Φ
= 4mm
83,3mm
7,45mm
1400mm
40mm min
Ø46mm max