MONITORING MENU :

SET and ESC buttons are used to switch between menus in the monitoring mode. If the device is left
unattended for 60 seconds in any menu other than the real time and date, it returns to the real time and
date screen.

Real Time

and Date

Menu

Sunrise Time

Menu

Sunset Time

Menu

Program

Activity Time

Menu

Activation

Time for C1

Relay(Hours)

Operation

Count for C1

Relay

Activation

Time for C2

Relay(Hours)

Operation

Count for C2

Relay

Program activity time menu shows the programs, which are stored on the device, in order according to
program activity time. The active or finished programs can be shown with UP or DOWN buttons. The
programs with a     sign next to them are the programs which are still active.

DTR 20 Menu Settings

If the “

SAVE

” option doesn’t get accepted when returning to the monitoring menu, the changes

which are made in the DTR 20 menus will be discarded. This isn’t the case for “

TIME SETING

”

menu.  The  changes  which  are  done  in  “

TIME  SETING

”  menu  are  applied  immediately.

When none of the keys are pressed in the programming menu, the device returns to monitoring menu and
any changes which were made will be discarded. Refer to the menu map when configuring the DTR-20
menus.

 Program Menu:

There are 32 programs available to program between P01 and P32. The available settings for programs
are relay selection, activation time, activation day, deactivation time, time conflict query and save. In
addition to these, an appointed program has two additional settings as “

EDIT

” and “

DELETE

”. If “

EDIT

” is

selected for an appointed program, the existing settings of that program is shown and can be reconfigured.
If “

DELETE

” is selected for an appointed program, that program will be deleted permanently.

Output Selection ( 

PXX-OUT

 ):

DTR-25 has 2 relay outputs as C1 and C2. The user must choose between C1 and C2 as the relay output
which he want to control.

Activation Time Setting ( 

PXX-ON

 ):

There are 3 parameters: Time, sunrise and sunset. The user can select and set any of the 3 parameters
which suits the application best.

Time Parameter ( 

TIME

 ):

This parameter is the adjustment of the relay according to the real time clock. If this parameter is selected,
the user can enter an activation time between 00:00:00 (HH:mm:ss) and 23:59:59.

Sunrise Parameter ( 

SUNRISE

 

):

This parameter is the adjustment of the relay according to sunrise time which is calculated in reference
to the local coordinates and date. If this parameter is selected, the user can enter an activation time
adding or substracting 9:59:59(HH:mm:ss) to the local sunrise time. If the time after the substraction
corresponds to the day before, this parameter is adjusted as 00:00:00 for the current day.

Sunset Parameter ( 

SUNSET

 ):

This parameter is the adjustment of the relay according to sunset time which is calculated in reference
to the local coordinates and date. If this parameter is selected, the user can enter an activation time adding
or substracting 9:59:59(HH:mm:ss) to the local sunset time. If the time after the addition corresponds to
the day after, this parameter is adjusted as 23:59:59 for the current day.

16:12:10

MO

18:45:52

C1:

C2:

SUNRISE

MO

07:22:00

C1:

C2:

SUNSET

MO

16:36:00

C1:

C2:

PO1-C1

MO

05:44:00

C1:

C2:

C2-SHOT

MO

000000

C1:

C2:

C2-TIME

MO

000000

C1:

C2:

C1-SHOT

MO

000000

C1:

C2:

C1-TIME

MO

000000

C1:

C2:

All manuals and user guides at all-guides.com

Summary of Contents for DTR-20

Page 1: ...A5120 Rev 2 DTR 20 User Manual and Menu Map Vertrieb durch TDE Instruments GmbH All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...lasts longer Reserve battery should only be changed by the authorized service MANUAL MODE In order to use the relay outputs manually DTR 20 has to be in the monitoring mode The DOWN button is used to...

Page 3: ...ng settings of that program is shown and can be reconfigured If DELETE is selected for an appointed program that program will be deleted permanently Output Selection PXX OUT DTR 25 has 2 relay outputs...

Page 4: ...e 1 and 2 Merge Function The merge function does a logical AND operation In the common timeframe of the merged programs the corresponding relay becomes active This function can be used if at least two...

Page 5: ...e local time is about to reach 02 00 00 and the clocks are turned 1 hour backward to 01 00 00 on the last Sunday of October USA Parameter According to the European DST settings the DST starts when the...

Page 6: ...s selected after the relay relays is are activated or deactivated by a program in the program flow the manual mode for the relay relays will be disabled Timer Parameter TIMER When this parameter is se...

Page 7: ...main programming menu an approval promt is shown If there aren t any changes the monitoring menu is shown directly Factory Settings Program P01 C1 relay will be activated everyday 30 minutes after su...

Page 8: ...ime 32 Screen Size Accuracy Power Consumption Mechanical Features Equipment Protection Class Ambient Temperature Protection Class Installation Dimensions Weight Quantity in 1 Package Refresh Time Outp...

Page 9: ...nguage set in the Regional Settings Parameters for the Turkish Language Selection 15 Parameters for the English Language Selection 16 16 Displayed Name Cities Time Zone Displayed Name Cities Time Zone...

Page 10: ...o the previous selection The diagrams are for P01 and the programming is done the same way for the other programs PROGRAM MO P01 MO FREE SUNRISE MO 0 00 00 0 00 00 1 35 51 ALL DAYS MO YES P01 OFF MO T...

Page 11: ...CONFIRM MO YES ADJSTED MO PO1 PO1 MO FULL 1 2 3 4 5 6 7 1 2 3 4 5 6 7 PROGRAM MO SAVE MO YES 16 08 10 MO 16 41 21 P01 ON MO TIME 3 sec SET C1 C2 C1 C2 C1 C2 C1 C2 C1 C2 C1 C2 C1 C2 C1 C2 C1 C2 C1 C2 C...

Page 12: ...MO 000000 C1 C2 16 12 10 MO 18 45 52 C1 C2 SUNRISE MO 07 22 00 C1 C2 SUNSET MO 16 36 00 C1 C2 PO1 C1 MO 05 44 00 C1 C2 Press for 3 seconds C1 C2 C1 C2 C1 C2 C1 C2 C1 C2 C1 C2 C1 C2 C1 C2 C1 C2 C1 C2...

Page 13: ...s to FREE Program stays unchanged PROGRAM MO PO1 MO FULL P32 MO FREE CONFIRM PO1 EDIT DELETE yes no PO1 ON TIME sunrse sunset 00 00 00 0 00 00 HH mm ss HH mm ss ALL DAYS MONDAY FRIDAY PO1 OFF TIME sun...

Page 14: ...shown The sub menu titles are shown on the menu flow diagram These parameters are shown for 3 seconds To prolong this time ESC UP or DOWN buttons should be pressed If the SET button is pressed the sho...

Page 15: ...ONTH W WEEK W DAY W HOUR CUSTOM DAYLIGH DISABL 3 30 12 00 12 00 3 00 REGIONL MO SETING LANGUAG MO POSITIO MO MANUAL TIMEZON MO 3 30 DAYLIGH MO SAVING TIMEZON TIMEZON TIMEZON TIMEZON SUMMER MO TIME WIN...

Page 16: ...13 CHANGED MO CENTURY CLOCK 20 53 40 DATE 13 09 11 DATE 20 09 89 CLOCK 20 43 50 CHANGED MO CLOCK CHANGED MO DATE HOLIDAY MO LOCK MANUAL MO MODE HOLIDAY MO 1 FREE START MO DATE END MO DATE HOLIDAY MO...

Page 17: ...PASWORD MO DISABL PASWORD DISABL PASWORD MO WRONG ACTIVE PASWORD MO CHANGE NEWPASS 0000 NEWPASS 0000 REENTER 0000 PASWORD 0000 PASWORD 0000 CONFIRM N0 REENTER 0000 0001 PASWORD MO CHANGD ENTRY MO WRO...

Reviews: