Mounting the SSA
Enterasys S-Series Stand Alone (SSA) Hardware Installation Guide 2-3
Mounting the SSA
You
can
install
an
SSA
on
a
desktop
or
in
a
rack.
For
more
information
about
desktop
installation,
see
Using
the
SSA
rail
kit
shipped
with
the
SSA,
you
can
install
the
SSA
in
three
types
of
racks:
•
Four
‐
post
rack
—
See
•
Two
‐
post
rack
(7
‐
inch
posts)
—
See
•
Two
‐
post
rack
(3
‐
inch
posts)
—
See
If
you
are
installing
the
SSA
in
a
rack,
Enterasys
Networks
recommends
that
you
install
the
SSA
in
a
four
‐
post,
48.26
‐
centimeter
(19
‐
inch)
equipment
rack.
In
each
of
the
three
rack
types,
you
can,
optionally,
secure
the
rear
of
the
SSA
to
tabs
on
the
rails.
For
more
information
about
securing
the
rear
of
the
SSA,
see
If
you
plan
to
cable
your
SSA
with
SFP
or
SFP+
pluggable
transceivers,
you
may
need
to
have
3–4
inches
of
clearance
at
the
front
of
the
SSA.
The
installation
site
must
be
within
reach
of
the
network
cabling
and
meet
the
requirements
listed
below:
•
Appropriate
grounded
power
receptacles
must
be
located
within
7
feet
of
the
site.
•
A
temperature
of
between
5°C
(41°F)
and
40°C
(104°F)
must
be
maintained
at
the
installation
site
with
fluctuations
of
less
than
10°C
(18°F)
per
hour.
Caution:
If you are installing an SSA in a four-post or two-post rack, you must use the SSA rail kit to
install the SSA in the rack. Do not attempt to secure the SSA directly to the rack using the small
front mounting ears.
Precaución:
Si instala un SSA en un estante de cuatro o de dos postes, debe usar el kit de rieles
de SSA para realizar la instalación. No intente asegurar el SSA directamente en el estante usando
las lengüetas de montaje delanteras pequeñas.
Caution:
To ensure proper ventilation and prevent overheating, leave a minimum clearance space
of 5.1 cm (2.0 in.) at the left, right, and rear of the device.
Precaución:
Para asegurar una buena ventilación y evitar que el sistema se sobrecaliente, deje un
espacio mínimo de 5.1 cm (2 pulgadas) con respecto a los lados y a la parte posterior del aparato.
Warning:
Before rack-mounting the device, ensure that the rack can support it without
compromising stability. Otherwise, personal injury and/or equipment damage may result.
Advertencia.
Antes de montar el equipo en el rack, asegurarse que el rack puede soportar su peso
sin comprometer su propia estabilidad, de otra forma, daño personal o del equipo puede ocurrir.
Warnhinweis:
Überzeugen Sie sich vor dem Einbau des Gerätes in das Rack von dessen
Stabilität, ansonsten könnten Personenschäden oder Schäden am Gerät die Folge sein.
Summary of Contents for SSA-G1018-0652
Page 2: ......
Page 12: ...x ...
Page 16: ...xiv ...
Page 20: ...Getting Help xviii About This Guide ...
Page 46: ...Completing the Installation Pin Out Descriptions 2 22 Installation ...
Page 64: ...Using the OFFLINE RESET Button 3 18 Troubleshooting ...
Page 68: ...Regulatory Compliance A 4 Specifications ...
Page 76: ...Management of PoE Power to PDs C 4 About PoE Power over Ethernet ...