Configuring MAC Locking
18-46
Security Configuration
Configuring MAC Locking
This
feature
locks
a
MAC
address
to
one
or
more
ports,
preventing
connection
of
unauthorized
devices
through
the
port(s).
When
source
MAC
addresses
are
received
on
specified
ports,
the
switch
discards
all
subsequent
frames
not
containing
the
configured
source
addresses.
The
only
frames
forwarded
on
a
“locked”
port
are
those
with
the
“locked”
MAC
address(es)
for
that
port.
There
are
two
methods
of
locking
a
MAC
to
a
port:
first
arrival
and
static.
The
first
arrival
method
is
defined
to
be
locking
the
first
n
number
of
MACs
which
arrive
on
a
port
configured
with
MAC
locking
enabled.
The
value
n
is
configured
with
the
set
maclock
firstarrival
command.
The
static
method
is
defined
to
be
statically
provisioning
a
MAC
‐
port
lock
using
the
set
maclock
command.
The
maximum
number
of
static
MAC
addresses
allowed
for
MAC
locking
on
a
port
can
be
configured
with
the
set
maclock
static
command.
You
can
configure
the
switch
to
issue
a
violation
trap
if
a
packet
arrives
with
a
source
MAC
address
different
from
any
of
the
currently
locked
MAC
addresses
for
that
port.
MACs
are
unlocked
as
a
result
of:
•
A
link
down
event
•
When
MAC
locking
is
disabled
on
a
port
•
When
a
MAC
is
aged
out
of
the
forwarding
database
when
FirstArrival
aging
is
enabled
When
properly
configured,
MAC
locking
is
an
excellent
security
tool
as
it
prevents
MAC
spoofing
on
configured
ports.
Also
if
a
MAC
were
to
be
secured
by
something
like
Dragon
Dynamic
Intrusion
Detection,
MAC
locking
would
make
it
more
difficult
for
a
hacker
to
send
packets
into
the
network
because
the
hacker
would
have
to
change
their
MAC
address
and
move
to
another
port.
In
the
meantime
the
system
administrator
would
be
receiving
a
maclock
trap
notification.
Purpose
To
review,
disable,
enable,
and
configure
MAC
locking.
Commands
administrative
egress
Port status as assigned by the set vlanauthorization egress command
operational egress
If authentication has succeeded, displays the VLAN id assigned for egress.
vlan id
If authentication has succeeded, displays the assigned VLAN id for ingress.
Table 18-5
show vlanauthorization Output Details (Continued)
Output
What It Displays...
For information about...
Refer to page...
Summary of Contents for SecureStack C2
Page 1: ...SecureStack C2 Stackable Switches Configuration Guide Firmware Version 5 1 xx P N 9033991 16 ...
Page 2: ......
Page 28: ...xxvi ...
Page 106: ...set ssl 3 52 Basic Configuration ...
Page 226: ...Creating a Basic SNMP Trap Configuration 6 38 SNMP Configuration ...
Page 278: ...show spantree nonforwardingreason 7 52 Spanning Tree Configuration ...
Page 302: ...set garp timer 8 24 802 1Q VLAN Configuration ...
Page 448: ...show dhcp pool configuration 14 30 DHCP Server Configuration ...
Page 454: ...no license advanced 15 6 Preparing for Router Mode ...