Logging and Network Management Command Set
Configuring System Logging
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
11-3
11.2.1.1 set logging
Use this command to globally disable or re-enable Syslog on the device.
set logging
{
enable
|
disable
}
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This command shows how to disable Syslog:
11.2.1.2 show logging all
Use this command to display all configuration information for system logging.
show logging all
Syntax Description
None.
Command Defaults
None.
enable
|
disable
Enables or disables Syslog.
Matrix>
set logging disable
NOTE:
Most system messages are logged at severity level of 6 (Notice). By default, the
logging applications are set to 5 (Warning),
which will suppress level 6 (Notice)
messages from the console session. To view most of the logging of configuration
messages on the console session, ACL hits etc., the
set logging application
command should be used as described in
Section 11.2.1.12
to set the logging level for
applications to 6 or higher.