ENSIM SENSORS ELV 00 Operating Manual Download Page 1

OPERATING
MANUEL

FLOAT VALVE

ELV

Model  :

Information in this manual is reviewed and completely reliable. Responsibility is not assumed due to any typing error.
Products in this manual are available only for information purpose and they may be changed without notice.

Important Notes:

Models :

Used Symbols :

ELV 00 , ELV 08
ELV 10 , ELV 12 , ELV 15
ELV 16 , ELV 18
ELV 21 , ELV 31 , ELV 41 , ELV 51 , ELV 52

ELV 41f , ELV 51f
ELV 65f , ELV 81f ,  ELV 101f

1

: Caution

: Note

Disposal

Table of Contents

 :

1.  General Information....................................................................................................................................................2
2.  Installation ....................................................................................................................................................................3
3.  Failure Detection.....................................................................................................................................................................9
4.  Disassembly of Instrument ............................................................................................................................................................9
5.  Service ...............................................................................................................................................................................................9
6. Recalibration........................................................................................................................................................9
7.  Repair........................................................................................................................................................................................9
8. Disposal.............................................................................................................................................................9
9. Terms of Warranty  ..............................................................................................................................................................................9
10.Terms of Return ………………………………………………………………………………………........................................…..............…9

Please read this manual carefully before installation of the 

level switch

. User is responsible for accidents and losses arising

from failure to comply with the warnings in this manual.

In the event that 

level switch

 is broken, take measures in order to prevent accidents and losses which can occur in its system.

There is not any fuse and circuit breaker on the instrument; they should have been added to the system by the user.

This manual should be stored in an easily accessible place for subsequent use.

The manufacturer's liability cannot exceed the purchase price of the device according to the law.

Do not make any modification on the instrument and do not try to repair it. Reparation should be made by authorized service staff.

Do not operate the system before making assembly in compliance with the assembly chart related to the instrument.

Products which do not contain label and serial number are considered to be excluded from the warranty scope.

The instrument's useful life, determined and announced by the ministry, is 10 years.

Model : 34-2022-007

Summary of Contents for ELV 00

Page 1: ...or accidents and losses arising from failure to comply with the warnings in this manual In the event that level switch is broken take measures in order to prevent accidents and losses which can occur in its system There is not any fuse and circuit breaker on the instrument they should have been added to the system by the user This manual should be stored in an easily accessible place for subsequen...

Page 2: ...nder 5 C 1 3 Operating Princible It is used checking liquid level in the tanks Lenght of flot can be adjusted with the arm which is designed horizontally and vertically with the arm with closed design Valve is closed by increasing liquid level by using temperature resistance isolation material or on the contrary valve is opened and starts to discharge with increase in the liquid level When levelde...

Page 3: ...cise carry it carefully and prevent to be damaged It should be guaranteed that there are not any magnetic particles 2 2 General Installation Stages Remove level switch from the box carefully Check whether gasket is appropriate for fluid or not If is not appropriate contact with the producer Then apply below mentioned explanations according to structure of the design 2 3 Special Notes Please ensure...

Page 4: ...610 110 135 160 160 190 25 25 25 25 25 20 20 20 20 20 53 5 53 5 53 5 53 5 53 5 3 4 BSP 3 4 BSP 3 4 BSP 3 4 BSP 3 4 BSP 1 2 BSP 1 2 BSP 1 2 BSP 1 2 BSP 1 2 BSP Model Float ØD H L h l k t R r Dimensions All dimensions are stated as mm ELV 16 18 3 4 BSP Nut 3 5 m h Max 8 bar Max 2 5 kg Model Connection Max flow range Working Pressure Weight L Lever Float R r t l k ØD h H ELV 16 18 Nut Seal Body Pisto...

Page 5: ...nge Working pressure Weight Important Note If you mounted the level switch so close to the pump you must extend the arm or increase the number of the balls Important Note If you mounted the level switch so close to the pump you must extend the arm or increase the number of the balls Specification ELV 41f ELV 51f 1 1 2 Flanged 12 5 m h Max 5 bar Max 3 4 kg 2 Flanged 16 5 m h Max 5 bar Max 3 5 kg Mo...

Page 6: ...ston Seal Lever Float Piston Bracket Float ELV 65f 81f 101f 1 2 BSP Thread Lever Float Ø125 L Model 2 1 2 Flanged 20 m h Max 3 bar Max 8 kg ELV 65f ELV 81f ELV 101f 3 Flanged 35 m h Max 3 bar Max 10 5 kg 4 Flanged 50 m h Max 3 bar Max 12 kg Connection Max flow range Working pressure Weight 1250 1250 1250 290 290 290 73 5 73 5 73 5 20 20 20 1 1 2 BSP 2 BSP 3 BSP ELV 65f ELV 81f ELV 101f 280 280 280...

Page 7: ...0007 1 1 2 BSP Nut 0008 2 BSP Nut 0009 DN 40 PN 16 Flanged 0105 DN 50 PN 16 Flanged 0106 DN 65 PN 16 Flanged 0107 DN 80 PN 16 Flanged 0108 DN 100 PN 16 Flanged 0109 Special x 7 OUTPUT CONNECTION Special x 8 OPTIONAL EXAMPLE Note Output mesaurement of sample models can be made standardly None 0 1 2 BSP 0004 3 4 BSP 0005 1 BSP 0006 ELV 18 0 001 1 82 0005 0004 0 ELV 18 R 3 4 Single Float ELV 00 ELV 0...

Page 8: ...erwise instulation problem may cause Please do not drop otherwise the characteristics might be changed Vibration might be caused instability Please avoid using with liquids which damage materials of parts otherwise quality can not be maintained accurately Do not remove the float from connection part Because its pin might be damaged WARNINGS Please pay attention to following matters in order to ope...

Page 9: ... should be repaired only by authorized service 4 Disassembly of Instrument Instrument should be disassembled while feeding and pressure is not available 5 Service 6 Recalibration Calibration is not required during long period useful life of a level switch 7 Repair 96Manufacturer Address If irreparable breakdowns occur the instrument should be sent to us for repair purpose Before this the instrumen...