background image

APPLICATIONS

As shown below, the 5820 receives GPI information from a third party automation system.
The module is then configured to send messages to any Avenue module on the network to
recall memory registers. The optional Remote Control Panel shown here can monitor
status of the GPI inputs. From the serial interface port of the 5820, an external device can
also activate the same recall functions. The interface supports both RS-232 and RS-422
standards and uses a simple ASCII-based protocol for easy interconnection.

INSTALLATION

Plug the 5820 module into any one of the slots in the 1 RU or 3 RU frame. Install the
plastic overlay provided onto the corresponding group of rear BNC connectors associated
with the  module location. Note that the plastic overlay has an optional adhesive backing
for securing it to the frame. Use of the adhesive backing is only necessary if you would
like the location to be permanent and is not recommended if you need to change module
locations.  This module may be hot-swapped (inserted or removed) without powering down
or disturbing performance of the other modules in the system.

CABLING

Cabling to the 5820 module is done through the 

Control

connector at the bottom of the

module backplane. Refer to the next section for control interface connections.

Model 5820 GPI/Serial Interface Module

5820-3

5820

5600

5430/5440

Automation

Avenue Control Network

GPIs

Optional Control Panel "Shot Box"

System

5820 GPI/Serial Interface Module Application

Summary of Contents for Avenue 5820

Page 1: ...is data pack is organized into the following sections Module Overview Applications Installation Cabling Module Configuration and Control Front Panel Controls and Indicators Avenue PC Remote Control Avenue Touch Screen Remote Control Troubleshooting Software Updating Warranty and Factory Service Specifications 5820 1 Model 5820 GPI Serial Interface Data Pack Revision 2 1 SW v1 1 0 ENSEMBLE D E S I ...

Page 2: ...etwork When a GPI or serial command is received by the 5820 it sends a configuration recall command to the corresponding Avenue module Using M2M Module To Module communication the 5820 can communicate with any other module in any Avenue frame on the network That module then recalls the specfied memory register An optional 1 RU control panel is available to serve as a shot box It has eight illumina...

Page 3: ...ovided onto the corresponding group of rear BNC connectors associated with the module location Note that the plastic overlay has an optional adhesive backing for securing it to the frame Use of the adhesive backing is only necessary if you would like the location to be permanent and is not recommended if you need to change module locations This module may be hot swapped inserted or removed without...

Page 4: ...gram below The Remote Control Panel can be rack mounted in a standard 19 inch equipment rack Connect the universal in line power supply provided to the connector at the left rear of the panel The power supply is auto sensing and requires no adjustments Up to eight Remote Control Panels can be connected in parallel for multipoint control Panels are connected together via the DB 9 pin loop through c...

Page 5: ...ol connector pins as shown below Each GPI pushbutton should be wired with closure to ground to trigger a crosspoint It can also simultaneously output status to light LEDs that are wired to ground as indicated in the diagram below Model 5820 GPI Serial Interface Module 5820 5 Customer Supplied GPI Device Switches 5820 Control Connector HDB 15 Male 1 2 3 4 5 6 7 8 15 14 12 11 10 9 8 7 3 6 13 Pin 1 P...

Page 6: ...using the Avenue PC option refer to the Avenue PC Remote Configuration section of this document For setting the parameters remotely using the Avenue Touch Screen option refer to the Avenue Touch Screen Remote Configuration section of this data pack following Avenue PC Front Panel Controls and Indicators Each front edge indicator and switch setting is shown in the diagram below Model 5820 GPI Seria...

Page 7: ... inputs as follows GPI 1 8 Mode set to On GPI High GPI triggered by pulse going high or GPI Low GPI triggered by pulse going low Mem Reg select the memory register 1 5 on the corresponding module that has been configured for recall Frame Adr enter the AveNet address of the frame containing the module you wish to control Slot Number enter the Slot Number of the module in the selected frame A Status...

Page 8: ...able GPI port Set the parameters for each of the GPI inputs as follows GPI 1 8 Mode set to On GPI High GPI triggered by pulse going high or GPI Low GPI triggered by pulse going low Mem Reg select the memory register 1 5 on the corresponding module that has been configured for recall Frame Adr enter the AveNet address of the frame containing the module you wish to control Slot Number enter the Slot...

Page 9: ...ld be blinking slowly and in unison with other modules if System module is present If not try removing it and plugging it in again System module may not be working properly if installed You may also refer to the technical support section of the Ensemble or Graham Patten web sites for the latest information on your equipment at the URLs below http www ensembledesigns com support SOFTWARE UPDATING S...

Page 10: ...other suggestions for identifying the problem and recommend possible solutions Factory Service If you return equipment for repair please get a Return Material Authorization Number RMA from the factory first Ship the product and a written description of the problem to Ensemble Designs Inc Attention Customer Service RMA 870 Gold Flat Rd Nevada City CA 95959 USA 530 478 1830 Fax 530 478 1832 service ...

Page 11: ...32 RS 422 General Specifications Power Consumption 5 0 Watts Temperature Range 0 to 40 degrees C ambient all specs met Relative Humidity 0 to 95 noncondensing Altitude 0 to 10 000 ft Fusing 1 5 Amp PTC resettable fuse Setup User Selectable Due to ongoing product development all specifications subject to change 5820 11 ...