1427950   TensMed 931 
 

 6WDQGDUG$FFHVVRULHV

 
The following accessories are included with your TensMed 931: 
 
3444001 

Electrode cable 2mm, 2 pc in conformity with FDA CFR 898 

3444058 

Self adhesive electrode 50x90 mm, 8 pc.  

1427754 

User manual TensMed 931 

 

Alkaline AA 1,5 Volts (LR6) Batteries 

 Carry 

Pouch 

  

 2SWLRQDO$FFHVVRULHV

 
3444056 Self 

adhesive electrodes, size 32mm Ø, 1 pack = 10 sheets of 4 pc 

 

3444135 

Self adhesive electrodes, size 50mm Ø, 1 pack = 10 sheets of 4 pc  

3444143 

Self adhesive electrodes, size 70mm Ø, 1 pack = 10 sheets of 4 pc 

3444057 

Self adhesive electrodes, size 50x50mm, 1 pack = 10 sheets of 4 pc 

3444058 

Self adhesive electrodes, size 50x90mm, 1 pack = 10 sheets of 4 pc 

3444146 

Self adhesive electrodes with double lead, size 50x100mm, 1 pack = 10 sheets of 2 pc 

 
 

 ,QVWDOODWLRQ

 

,QVHUW%DWWHULHV

:  

Insert two batteries. (A diagram inside the battery compartment shows how to insert the batteries 
correctly.)  
 
To check if the batteries have been correctly fitted, press the ON/OFF button once and the LCD display 
will start up and the LED Lights will come on.  Press the ON/OFF button again to switch the unit off. 

 

Use only AA Alkaline 1.5 volt batteries (LR6).   
Do not mix old and new batteries.   
The battery contains material that is noxious to environment. You should attend the local regulations 
when disposing the battery. 

$WWDFK/HDGV

:  

Unravel leads and insert the plug(s) into either socket in the end of the unit. If using only one lead use L1 
(as marked on the unit next to the socket). 

$WWDFK(OHFWURGHVWROHDGV

Remove electrodes from the bag and connect to the leads.   
Simply push the plug on the electrode pigtail into the socket on the lead. 
 
 

 $SSOLFDWLRQRI(OHFWURGHV

&$87,21

• 

Connection of accessories other than the ones specified by the manufacturer can adversely 
affect the safety of the patient and correct functioning of the equipment, and is therefore not 
permitted. 

 

127(

• 

The description below applies to electrotherapy applications in general. The electrolytic effects 
mentioned do not apply to the Tensmed 931 as this device only generates fully balanced TENS 
currents, that do not contain a DC component. 

 

Summary of Contents for TensMed 931

Page 1: ...7HQV0HG User Manual...

Page 2: ...Copyright Enraf Nonius B V P O Box 12080 3004 GB Rotterdam The Netherlands Tel 31 0 10 20 30 600 Fax 31 0 10 20 30 699 info enraf nonius com www enraf nonius com Part number 1427754_41 August 2005...

Page 3: ...7HQV0HG Operating Instructions...

Page 4: ...URGHV 7 1 Before treatment 8 7 2 Self adhesive electrodes 8 7 3 Electrolytic effects 8 7 4 Current density 8 7 5 Connection and disconnection reactions 8 2SHUDWLQJ QVWUXFWLRQV 8 1 Operator Controls 9...

Page 5: ......

Page 6: ...Liability law implies amongst other things that once a period of 10 years has elapsed after a product has been brought into circulation the manufacturer can no longer be held responsible for possible...

Page 7: ...ions and hazards associated with using any electrical stimulation device Observe the precautionary and operational decals placed on the unit Do not operate the TensMed 931 when connected to any unit o...

Page 8: ...conductive medium The irritation can usually be reduced by using an alternative conductive medium or alternate electrode placement See also chapter 3 Precautionary Instructions for general Warnings a...

Page 9: ...ly fitted press the ON OFF button once and the LCD display will start up and the LED Lights will come on Press the ON OFF button again to switch the unit off Use only AA Alkaline 1 5 volt batteries LR...

Page 10: ...2 10 the maximum permissible current density is 2 mA RMS per cm With the rubber electrodes this requirement is automatically met as the output current of the stimulator is limited to 50 mA RMS With s...

Page 11: ...ters that can be selected are Waveform Frequency Pulse Width Ramp Up Work Time Ramp Down Rest Time Synchronous Alternating Timer The 3 86 function interrupts a Program which is using the Timer It only...

Page 12: ...selected The first segment lights as soon as intensity is above zero Each subsequent segment represents approx 4 5V 6 V in high intensity mode 6DIHW IHDWXUHV If the unit is accidentally switched on an...

Page 13: ...tangular Rectangular unipolar alternating Treatment time 10 20 30 45 60 90 minutes or continuous Synch Alternating Synchronous between Ch1 and Ch2 Ramp Time 0 5 0 seconds in steps of 0 25 seconds Work...

Page 14: ...s is restricted to one program allowing change of Intensity and Timer only Any manual settings in 3URJUDPV 6 RU 7 will be retained if doctor lock is set You may therefore prescribe and lock any TENS s...

Page 15: ...y the performance of the unit When the electrodes initially lose their adhesive quality it is possible to reactivate the adhesiveness by applying a fine spray of water When used on clean skin and stor...

Page 16: ...put current into 1kOhm maximum setting P LJXUH Rectangular Monophasic Alternating Waveform Output current into 500 Ohm LJXUH Timing Relationship between L1 and L2 Pulses PULSE WIDTH POSITIVE AMPLITUDE...

Page 17: ...class according to IEC 60601 1 type BF Dimensions 144 x 80 x 27 5 mm h x w x d Weight 180 gr incl Batteries Environmental conditions for transport and storage Temperature 10 to 50 C Relative humidity...