Troubleshooting an Enphase System
2014 Enphase Energy Inc.
August 2014
41
GFI Tripped
This condition occurs only with the M215, M190, D380, M210, M200, and M175 microinverters. A solid
red status LED on the microinverter indicates a ground fault (GFDI) error. The LED remains red and the
Envoy continues to report the fault until the error has cleared.
If a microinverter registers a GFI Tripped condition, you can attempt to clear this condition through the
Envoy Interface. An Envoy is required to send the
clear-gfi message
to clear the condition. If the
condition does not clear after you perform the following procedure, contact Enphase Energy customer
support at
To send the
clear-gfi
message to a microinverter:
1. From the Administration menu, choose
Device Conditions and Controls
.
NOTE
: Do not check the box in the
Select
column.
2. Click on the
serial number
of the unit showing the GFI condition.
The Control Flags screen appears.
CAUTION
: : Do not select the
reboot
and
cmd-alert
control flags unless recommended by
Enphase. The functions are:
reboot
- reboots the inverter
cmd-alert
- clears a condition flag for a command sent