background image

 

Section 15 

 

00-02-0831 

2013-03-21 

1 -

 

Introduction 

The DF series are diaphragm-operated ‘hydrostatic head pressure’ level switches. A pressure 

sensitive diaphragm operates a snap-switch that can be wired directly to electric pilot circuits to 

control pumps at pre-determined levels. A typical application is starting and stopping electric 

driven pump(s) to maintain tank levels. This series of level switches can also be used with 

engine driven pumps. 

The nitrile sensing-diaphragm is impervious to most liquids and is sensitive enough to control 

levels with ¼ in. (6 mm) repeatability. See the next section, 

Basic Operation

, for limits of 

switch trip-point adjustability. The case is aluminum with a glass-filled nylon bottom plate. 

This is a highly reliable level switch and can be worked into almost any new or existing system 

without major modification or special tools. 

The 

DF755

 and 

DF757

 are suitable for atmospheric tanks in non-hazardous areas. The SPDT 

snap-switch for the 

DF755

 is preset for a 4 in. (102 mm) differential in liquid level. The 

DF757

 

trip point is adjustable over a 108 in. (2743 mm) range. 

Basic Operation 

As the liquid level rises, hydrostatic head pressure is applied to the diaphragm (

A

) as shown 

below. The diaphragm moves upward pressing the actuator arm (

B

) to activate the snap-

switch (

C

). 

Model DF755 is factory set and operates at approximately 2 in. (51 mm) and 6 in. (152 mm) 

above the level at which the diaphragm is mounted. The trip point(s) for Model DF757 are 

adjustable between 2 in. (51 mm) and 110 in. (2794 mm) for high and low (make/break) 

operation by knobs (

D

). 

 

 

1-800-548-1191 - http://www.partdeal.com - [email protected]

Summary of Contents for Murphy DF Series

Page 1: ...00 02 0831 2013 03 21 Section 15 DFSeriesHydrostaticHeadLevel Switches Installation and Operations Manual 1 800 548 1191 http www partdeal com info partdeal com ...

Page 2: ...me The latest version of this manual can be found at www fwmurphy com Please read the following information before installing BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT Read and follow all installation instructions Please contact Enovation Controls immediately if you have any questions 1 800 548 1191 http www partdeal com info partdeal com ...

Page 3: ... Operation 1 Typical Applications 3 Water Flood Control Systems 3 Low Pressure Gas Blanket on Tank 3 Typical Wiring Diagrams 4 Installation of a Volume Air Cell 6 Overview 6 Specifications 8 Service Parts 9 1 800 548 1191 http www partdeal com info partdeal com ...

Page 4: ... THIS PAGE INTENTIONALLY LEFT BLANK 1 800 548 1191 http www partdeal com info partdeal com ...

Page 5: ...ttom plate This is a highly reliable level switch and can be worked into almost any new or existing system without major modification or special tools The DF755 and DF757 are suitable for atmospheric tanks in non hazardous areas The SPDT snap switch for the DF755 is preset for a 4 in 102 mm differential in liquid level The DF757 trip point is adjustable over a 108 in 2743 mm range Basic Operation ...

Page 6: ...nobs see the following drawings 2 To increase the low level set point rotate the lower knob counterclockwise NOTE If the adjustment shaft turns when rotating the adjustment knobs firmly grasp the adjustment shaft with a pair of needle nose pliers and then rotate the knob 1 800 548 1191 http www partdeal com info partdeal com ...

Page 7: ...edetermined level DF 5 stops the transfer pump As tank level falls to the set low level DF 6 starts the transfer pump If the tank level continues to fall due to the failure of the filters section DF 7 initiates shutdown of the transfer pump A DF755 located at this level will also operate backwash equipment DF 8 stops the injection pump before tank pumps completely out An OPL Series Pressure SWICHG...

Page 8: ... switches Starts at Low Level Stops at High Start motor when pre determined low level is reached and stop when high level is reached Keeps tank level within selected limits Motor starter is equipped with Hands Off Auto HOA Starts at High Level Stops at Low Start motor when pre determined high level is reached and stop when low level is reached Motor starter equipped with HOA 1 800 548 1191 http ww...

Page 9: ... level Shown at right Wire to Normally Closed NC terminal to shutdown on low level Dual Magneto Shutdown Shutdown dual magneto engines using a Murphy MS2120 Magnetic Switch Diagram at right shows hookup for low level shutdown Wiring changes and mounting locations are necessary for high level shutdowns 1 800 548 1191 http www partdeal com info partdeal com ...

Page 10: ...me sufficient pressure is applied to activate the internal snap switch this starts the pump As the liquid level is pumped down pressure decreases the snap switch reverses and the pump stops The pump is held in a standby condition An air purge may be required in the sensor line For additional information consult Enovation Controls Choosing a Volume Cell The volume cell should be constructed of mate...

Page 11: ...nstall the DF755 well above the highest water level and in a position that allows access for adjustment or repairs NOTE Periodically operate the pump manually until the water level reaches a point approximately in 13mm below the bottom of the Volume Cell This automatically recharges the unit and compensates for normal absorption of air into water Small electric air pumps are available to automatic...

Page 12: ...480 VAC 1 2 A 125 VDC 1 4 A 250 VDC DPDT optional 10 A 28 VDC 10 A 120 230 VAC Case Lid Aluminum standard Bottom Plate Glass filled Nylon Process Connection 1 NPT standard Maximum Pressure Rating 25 psi 172 kPa 1 72 Bar Conduit Connection electrical 1 2 NPT 1 800 548 1191 http www partdeal com info partdeal com ...

Page 13: ... connection 15050083 Bracket and movement repair kit 15000313 SPDT snap switch and insulator repair kit 5 amp 15000121 DF757 Description Part Number Cover aluminum 15050081 Case aluminum 15050594 Cover Screw 3 6 32 x 5 16 round head 80040607 SPDT snap switch and bracket assembly repair kit 5 amp 15000174 Screws 2 for switch bracket and assembly to case 6 32 x 1 4 round head 80040605 Spring and pis...

Page 14: ... THIS PAGE INTENTIONALLY LEFT BLANK 1 800 548 1191 http www partdeal com info partdeal com ...

Page 15: ... THIS PAGE INTENTIONALLY LEFT BLANK 1 800 548 1191 http www partdeal com info partdeal com ...

Page 16: ...1 800 548 1191 http www partdeal com info partdeal com ...

Reviews: