Authentication
B.1
Input data
For this example, we consider the following input data:
Parameter
Example
Input data
(Message to be authenticated)
1CFFDA03FB2700000268458D0140420906578AF791E6
5E2301
Source address (Message sender)
E50077010000
Security key
4DB34DB3070EFC6713FE39E13CF3C939
Authentication signature to be verified
0F0157D3
Table 57
–
Input data
From the data telegram and the commissioning telegram, we can derive the following pa-
rameters required for the authentication algorithm:
Parameter
Example
Source Address (little endian format)
0000017700E5
Length of input data
0x0019 (25 byte)
Sequence Counter (little endian format)
FB270000
Table 58
–
Derived input data