ENMET Recon IS Operation And Maintenance Manual Download Page 3

Recon IS

 

ENMET 

 

Manual Revision Date – June 15, 2017

 

P a g e

 | 

2

 

Manual Part No. – 80006-022 

 

 

1.0 Introduction 

The 

RECON-IS

 Series instruments are designed to detect toxic gases and oxygen concentrations in ambient air and has been 

approved to be used in hazardous locations.  Their one button operation, low power consumption and small size makes them ideal for 
use in many situations like, oil field, chemical plant and the mining industry as well as confined space entry, general construction and 
environmental industries. 

 

N

OTE

:

 

All specifications stated in this manual may change without notice.

 

 

1.1 Unpack 

Unpack the 

Recon IS 

and examine it for shipping damage.  If such damage is observed, notify both 

ENMET

 customer service 

personnel and the commercial carrier involved immediately. 

 

Regarding Damaged Shipments 

 

N

OTE

It is your responsibility to follow these instructions.  If they are not followed, the carrier will not honor any claims for 

damage.

 

 

 

This shipment was carefully inspected, verified and properly packaged at 

ENMET

 and delivered to the carrier in good 

condition. 

 

When it was picked up by the carrier at 

ENMET

, it legally became your company’s property. 

 

If your shipment arrives damaged: 

 

Keep the items, packing material, and carton “As Is.”  Within 5 days of receipt, notify the carrier’s local office and 
request immediate inspection of the carton and the contents. 

 

After the inspection and after you have received written acknowledgment of the damage from the carrier, contact 

ENMET

 Customer Service for return authorization and further instructions.  Please have your Purchase Order and Sales 

Order numbers available. 

 

ENMET

 either repairs or replaces damaged equipment and invoices the carrier to the extent of the liability coverage, usually 

$100.00.  Repair or replacement charges above that value are your company’s responsibility. 

 

The shipping company may offer optional insurance coverage. 

ENMET

 only insures shipments with the shipping company 

when asked to do so in writing by our customer.  If you need your shipments insured, please forward a written request to 

ENMET

 Customer Service. 

 

Regarding Shortages 

If there are any shortages or questions regarding this shipment, please notify 

ENMET

 Customer Service within 5 days of receipt at 

the following address: 

ENMET 

680 Fairfield Court 

Ann Arbor, MI 48108 

734-761-1270 Fax 734-761-3220 

Toll Free: 800-521-2978 

1.2 Check Order 

Check, the contents of the shipment against the purchase order.  Verify that the 

Recon IS 

is received as ordered.  If there are 

accessories on the order, ascertain that they are present.  Check the contents of calibration kits.  Notify 

ENMET

 customer service 

personnel of any discrepancy immediately 
 

1.3 Safety Settings 

Please read the following information carefully before using the detector.  

 

Do not use a damaged gas detector. 

 

Do not open the RECON-IS in a possible explosive working environment. 

 

Caution should be used if the background oxygen concentration is greater than 20.9% by volume since there is a greater 
risk of ignition of a combustible gas if present. Oxygen concentration in the air exceeding 20.9%vol could reduce the anti-
explosion feature of the detector.  ENMET Cooperation recommends that a "Bump Test" be performed to confirm sensor 
responds and to ensure that the audio, visual and vibration alarms are working properly. 

 

 

Summary of Contents for Recon IS

Page 1: ...ENMET 680 Fairfield Court Ann Arbor MI 48108 734 761 1270 Fax 734 761 3220 www enmet com Recon IS Operation and Maintenance Manual ...

Page 2: ... 9 6 0 MAINTENANCE 10 6 1 Maintenance Equipment 10 7 0 TECHNICAL DATA AND SPECIFICATIONS 11 8 0 TERMS AND CONDITIONS 12 8 1 Ordering Information 12 8 2 Delivery 12 8 3 Payment Terms 12 8 4 Warranty Information and Guidelines 12 8 5 Return Policy 12 9 0 INSTRUCTIONS FOR RETURNING AN INSTRUMENT FOR SERVICE 13 List of Figures Figure 1 Recon IS Features 3 Figure 2 Recon IS Display 4 Figure 3 Recon IS ...

Page 3: ...e have your Purchase Order and Sales Order numbers available ENMET either repairs or replaces damaged equipment and invoices the carrier to the extent of the liability coverage usually 100 00 Repair or replacement charges above that value are your company s responsibility The shipping company may offer optional insurance coverage ENMET only insures shipments with the shipping company when asked to...

Page 4: ...voltage alert etc Confidence beep With instruction it will display STEL value TWA value Max or Min gas level confidence beep information Self test on the gas sensor electric circuit battery audio alarm visual alarm and vibration alarm 2 1 RECON IS Configuration and Function See Figure 1 for location of features Feature Description 1 Visual Alarms LEDs 2 LCD Display Multi function See Section 2 2 f...

Page 5: ...el vibration alarm information checking activate deactivate confidence beep calibration etc In different status the function of the button is different as follows Function Action Turn on Press it for 3 seconds when it is power off Turn off Press it for 3 seconds when it is power on Cancelling sound or vibration alarm When alarming press it once Information checking In normal monitoring status pres...

Page 6: ...preset low alarming value and the high alarming value F Display STEL and TWA levels G Warm up Completion After passing the self test the detector starts warm up display shows 3 2 1 The unit is now operational and mentoring for the target gas concentration in the area If the self test fails the RECON IS will turn off automatically Please contact the ENMET for information 3 2 Turn Off RECON IS In th...

Page 7: ...wn 3 2 1 continue to hold the button until the screen displays H oP ON or H CL OFF release the button The status of the confidence beep is now changed NOTE With the confidence beep turned on the buzzer sounds once every 2 minutes which indicates the detector is working normally If the confidence beep is turned off there is no such indication when the detector is working normally 3 5 Zero Calibrati...

Page 8: ...e alarm sound Alarm LED Flashing Battery low voltage alert log appears At this time the detector can still work for 30 days at least When the battery is used up the detector will turn off automatically Sensor end of life indication Within 0 9 days before the sensor is used up screen will display as the right picture shows when the detector is self testing after turning on The figure means the numb...

Page 9: ...ing calibration points connect the cylinder regulator calibration gas and sensor cover to the instrument In 30 seconds display will indicate numbers Example 1476 and continue to change until the sensor response stabilizes If no gas input within 30s the system treats the calibration as failed Example CO See Table 1 Calibration Gas Sensor Respinding to Calibration Gas 5 If the standard gas is input ...

Page 10: ...ement WARNING the replacement sensor must be the same type as the sensor to be replaced Remove retaining screw open the RECON IS pull out the present gas sensor If the sensor is too tight please shake it slightly and then pull out it And then put new gas sensor into the sensor socket Make sure the sensor plug and socket is corresponding After replacement screw on the retaining screw CAUTION When p...

Page 11: ...signed model lithium battery 3V DC 1300 mAh Panasonic CR123A allowed The RECON IS is powered with a lithium battery do not discard with general waste Dispose of battery per local codes only Unauthorized removal adjustment or repair of the RECON IS will influence the performance of the device and the explosion proof 6 1 Maintenance Equipment ENMET calibration equipment part numbers Table 3 Calibrat...

Page 12: ...re 20 C 55 C Humidity 5 95 RH non condensing Electrical Power Lithium Battery DC3 6v CR123A Rechargeable Operating Time Continuous Non Alarm Conditions Approximately 8 Hours for Combustible LEL unit 300 Hours for CO H2S O2 units Charge Time 4 6 Hours Expected Sensor Life 2 years Ingress Protection IP 65 Approval Ratting Dimensions 2 4 x 3 9 x 1 3 inches 60x100x33mm Weight 5 ounces 140g NOTE All sp...

Page 13: ...tion by the Seller confirms that the product is defective it will be repaired or replaced at no charge within the stated limitations and returned prepaid to any location in the United States The Seller shall not be liable for any loss or damage caused by the improper use or installation of the product The Buyer indemnifies and saves harmless the Seller with respect to any loss or damages that may ...

Page 14: ...e Request Form assists in the expedient service and return of your unit and failure to provide this information can result in processing delays ENMET charges a one hour minimum billing for all approved repairs with additional time billed to the closest tenth of an hour All instruments sent to ENMET are subject to a minimum evaluation fee even if returned unrepaired Unclaimed instruments that ENMET...

Page 15: ... it Appears on Card RETURN SHIPPING METHOD UPS Ground UPS 3 Day Select UPS Next Day Air UPS ND Air Saver UPS 2 Day Air UPS Account FedEx Ground FedEx Air Express Saver FedEx Air Overnight Std FedEx Air 2 Day FedEx Air Overnight P 1 FedEx Account Insure Shipment Yes No Insurance Amount Product Name or Number Product Serial Number Describe Problem or Needed Service Warranty Claim Yes No CUSTOMER INF...

Reviews: