background image

 

 
 

ENIGMA II 

DR-81000 V2.00 

Digital Receiver 

 
 

 

 

 

User Manual 

Summary of Contents for DR-81000

Page 1: ...ENIGMA II DR 81000 V2 00 Digital Receiver User Manual ...

Page 2: ...stall Additional Line Cards 10 ENIGMA II Backplane View 10 4 The ENIGMA II Controls 11 The LCD Display 11 Power LED 11 Bat LED 11 Error LED 11 Link LED 11 Opt LED 11 RX LED 11 1 8 LEDs 11 DISPLAY key and LED 11 Function keys 11 ENTER key 11 Arrow keys 11 5 CPM2 Card 12 General Information 12 Features 12 CPM2 Startup Sequence 12 Normal Operation 12 The Status Row 13 List of Events 13 Review the Lis...

Page 3: ...ID Processing 26 Operating in Stand alone Mode 26 Line Card Menu 26 Audio Monitoring 26 Hang Up 27 Line Card Setup 27 Line Card Status 29 7 Power Card 30 Inputs and Outputs 30 Power Status Display 30 Battery Testing 30 Appendices 31 Appendix A System Event Table 0000 31 Appendix B Supported Communication Formats 32 Appendix C Trouble Shooting Guide 33 ...

Page 4: ...bility is built in and the telephone number of the calling party can be displayed printed stored in memory and forwarded to the automation computer The Line Cards also support the 2 way audio listen in The Line Cards are continuously supervised by the CPM Unit to ensure uninterrupted communication Any trouble conditions are immediately reported on the LCD screen and printer and or forwarded to the...

Page 5: ...ty at 10 40 bps 4 1 4 2 4 3 DTMF formats 3 2 and 4 1 with checksum formats optional Extended formats are optional Acron DTMF format Ademco Contact ID format Ademco SuperFast or High Speed format with or without parity Ademco Express format FBII Superfast format with or without parity SIA format 110 and 300 baud tone and data acknowledge Full level 2 partial level 3 support 1400Hz 2300Hz Dual tone ...

Page 6: ... and tests all system components If the CPM finds any malfunctioning unreliable components during the POS test it will stop and display the problem on the screen After the POS test had been finished the CPM resets the line cards in system and will switch to event list mode normal operation Operation with the default programming Without any changes to the factory default programming the receiver op...

Page 7: ...the printer to the receivers parallel printer output use a parallel printer cable IMPORTANT Using parallel printer cable with only one common ground wire is not recommended Computer Connections Connect the automation computer to the ENIGMA II DR 81000 serial COM A port using the supplied cable If the supplied cable is not long enough a serial Null modem cable can be used up to 15 meters in length ...

Page 8: ...X system 2 way audio communication needs bridging resistors with the same value as measured on the handset Using improper termination the line will be dropped when switched to 2 way Audio Mode Grounding To achieve the best resistance against static and electric noise and electromagnetic interference EMI connect the metal casing of the receiver to a grounding point Note that the grounding of the fr...

Page 9: ...former connect AC power to the Power Card Connect the battery cables to the battery outputs Use a 7 Ah or 15 Ah backup battery It is very important to connect protective ground shielding to the grounding terminal on the back of the PWR card This ensures the protection against static discharge A standard M5 nut is provided at the earthing point for connection This point can be connected to the grou...

Page 10: ... backplane do the following Install the LCM backplane to the extension subrack Remove the top cover of the desktop housing Mount the base subrack and the extension subrack together with subrack extender brackets Mount the top cover onto the top of the assembly Connect the power cable to the receivers power bus but do not connect the communications bus cable yet Push the new LCM Card into its place...

Page 11: ...reception in progress packet received while red light indicates transmission in progress packet sent in case repeater RX TX mode is enabled During Flash Update of the card the LED blinks slowly green 1 8 LEDs The LEDs 1 8 display status information of the line cards Continuous green light indicates standby mode the line is ok and the card is waiting for call Ring is signalled by fast blinking it t...

Page 12: ... 2 individual RS 232 serial ports COM A and COM B USB 2 0 High Speed slave port serial driver 10 Mbps Ethernet interface Serial port data rates can be set from 300 to 57600 baud Serial port data parameters data bits parity are programmable External acknowledge input 2 OC Programmable Outputs to follow different system status CPM2 Startup Sequence After power up the CPM2 waits for flash upgrade acc...

Page 13: ...e user numbers More about preset and user define libraries in the Libraries section The third column displays the number of the line card from which the event was received The line card numbers can be between 1 and 8 The two optional radio channels are represented by A and B System events are displayed with S and events received via the TCP IP port are shown with T If there are more receivers link...

Page 14: ...he four function keys 7 7 characters assigned to each Pressing a function key first will enter the first character assigned to it pressing it again shortly will enter the second assigned character and so on If the desired character is reached leaving the function key untouched for 2 seconds will finalize the character and the cursor will step onto the next position Pressing a different function ke...

Page 15: ...entral station operator to make a full receiver reset This can be useful if receiver malfunctions encountered There are three different levels of system reset The Factory reset will reset the receiver parameters to default This option might be useful if the user has misprogrammed the unit and wants to return to the factory default state This option is protected Figure 7 The Reset Menu The Memory f...

Page 16: ...ted if the connection on COM B is broken The default setting is printer off Link Mode As there are two independent serial ports are implemented on the receiver and both can be configured to report mode at the same time it is necessary to set when the link with the PC should be considered ok There are two options available here A OR B The link to the PC is considered good if there is connection in ...

Page 17: ...ignals The heart beat signals are used to test the communication link between the receiver and the central station computer when there is no reportable event in the memory buffer In this case the receiver sends so called heart beat signals to the computer in a programmed time interval and requires acknowledge for that If the acknowledge is missing or negative it assumes that the computer is failed...

Page 18: ...ings Here the asynchronous protocol for the serial port is set port speed number of databits and parity The port speed can be set between 300 and 57600 bps the number of databits can be set to 7 or 8 and the parity can be choosen as none even or odd The default setting is 9600 8 databits no parity NOTE The number of stopbits is always set to 1 This option is not changeable Receiver Number In multi...

Page 19: ...nowledge it for verification 1RR0sssssssssss ssss DC4 Where 1 Protocol ID Basic Signal RR Receiver number Heart beat signal DC4 Terminator 014h SIA Level 1 Protocol The SIA Level 1 Protocol is used to forward events received in SIA format When multiple events are received in one SIA data block SIA level 2 and 3 and the receiver is programmed to split the block to individual messages then reports t...

Page 20: ... ID RR Receiver number L Line Card ID Account ID code AAAAAA Account number Field separator XX SIA Event code or modifier YYYY Zone code user code time date info Data separator DC4 Terminator 014h Clock Signal Protocol The Clock Signal Protocol is used to transmit time and date information together with the events The Clock Signal is inserted to the serial protocol before the terminator character ...

Page 21: ...look for the driver automatically or to give the driver location manually Choose to install the driver from a list or specific location Now browse for the driver If you have already installed the Enigma II programmer software the driver can be found in the C Program Files ENIGMA II UsbDriver folder Before installing the driver Windows XP will prompt for confirmation as the driver is not passed the...

Page 22: ...e printing can also be fully disabled The receiver prints the events a similar way it displays on the screen 1234 Usr Open 01 005 02 06 20 15 40 23 will print as 2007 06 20 15 40 23 1234 Usr Open 01 005 02 The receiver prints first the date and the time of the event then the account number the event and the event qualifiers group partition zone user finally the Line Card number from which the even...

Page 23: ...ual configuration SIA level 3 with reverse channel restrictions Installation Up to 8 LC2 Line Cards can be installed in the Enigma II receiver The installation procedure of the Line Cards is described in Chapter 3 The actual line card number depends on which slot is the line card installed Positions 1 to 8 correspond to line card numbers 1 to 8 respectively LC2 Line Card Features High speed RISC m...

Page 24: ...d by mode In stand by mode the Line Card monitors the telephone line and waits for calls from digital communicators If the card is operating normally the following will be displayed in its status line READY The LC2 line cards check for the presence of the telephone line periodically when in stand by mode The line card LED indicates the line test by a short yellow pulse The line test is based on tr...

Page 25: ...type of faults can be the following BAD CRC CHECKSUM REPEAT FAILED UNKOWN FORMAT Note that although the Line Card can automatically identify most of the formats some of the communication formats must be enabled selected by programming 2 way Audio Mode There are two methods of activating 2 way Audio mode The first is the direct activation by special event types defined in sophisticated communicatio...

Page 26: ...lly and account always makes calls from the same telephone line the account ID and the calling number can be matched The assignment of the account code to the calling number by the line card makes possible to use advanced event checking options in the monitoring software on the PC E g filtering out invalid account calling number pairs and making account hijacking notifications Operating in Stand a...

Page 27: ...or of the line card telephone hybrid so that it might detect ringing If the number of rings set to 1 in this case the line card might stuck in a continuous communication attempt and will not be able to receive calls Due to this issue It is highly recommended to set the number of rings to minimum 2 to avoid such problems as more and more Service Providers change existing analog PCM connections to V...

Page 28: ...groups can be defined to activate 2 way Audio Mode as follow The first two values define an account group for 2 way audio The first two digits of the account code must be within the range defined by these values to allow 2 way audio for the given account Example 33 33 33xx accounts 18 2F 18xx 2Fxx accounts 00 00 no accounts allowed for 2 way audio The second two values define the event code range ...

Page 29: ...op the firmware version of the line card is displayed Beneath it the internal statistics of the line card are listed These values may help finding possible problems of the line card At the Line Card Status screen it is possible to reset the selected line card by pressing the RESET F3 button The line card will perform its power on test sequence and then starts up in standby mode ...

Page 30: ... battery If the LED blinks fast it indicates a problem of the power supply Battery Testing The Power Card checks for battery presence regularly and conducts an active battery test every hour It also makes the active test after the battery is connected to the receiver The battery testing does not affect receiver operation in any way as the system supply and the battery charger are independent of ea...

Page 31: ... is offline or out of paper PRINTER OK 8E Printer is ready RECEIVER RESET 8F Receiver has been reset TIME DATE SET 91 Time and Date has been set PROGRAM ACCESS 92 Program access via the serial port PROGRAM END 93 Programming finished via the serial port REMOTE ACCESS 94 Remote programming access REMOTE END 95 Remote programming finished MANUAL ACK 96 Manual acknowledgement ACCESS GRANTED 97 Access...

Page 32: ... 1400 Hz 1800 Hz pulse 40 bps 3 1 4 2 3 1 p 4 2 p 1400 Hz Radionics 2300 Hz 1800 Hz pulse 40 bps 3 1 4 2 3 1 p 4 2 p 2300 Hz Sescoa SuperSpeed 2300 Hz 1800 Hz pulse 40 bps 4 3 p 2300 Hz Contact ID Dual DTMF Contact ID 1400 Hz Sur Gard 2300 Hz DTMF 4 1 4 2 4 3 4 3 p 2300 Hz Sur Gard 1400 Dual DTMF 4 1 4 2 4 3 4 3 p 1400 Hz Ademco Express Dual DTMF 4 2 1400 Hz Acron DTMF Dual DTMF 4 8 1400 Hz Ademco...

Page 33: ...at consult manual for supported formats Problem Telephone line fault Solution Check the telephone line connections for cut or short Problem Fault call on the Line Card Solution Check that the handshake needed for the control panel is programmed for the Line Card Check that the handshake is being sent properly Use Audio Monitoring option Check that the control panel answers the handshake modify han...