4.1 Activation
The device supports the following activations on a LoRaWAN® network:
NONE: sensor not activated
1.
OTAA: the JoinEUI and the AppKey not setted, must be written to the device;
2.
OTAA MCF88: Over the air activation, fixed keys: JoinEUI = 904e915000000001, AppKey on
3.
request;
OTAA ENGINKO: Over the air activation, fixed keys: JoinEUI = 904e915000000001, AppKey on
4.
request;
ABP: requires writing to the device of NwkSkey, AppSkey, DevAddr.
5.
The device exits factory activated with NONE mode. On request devices can be shipped aleady
activated.
Note: in OTAA AppKey is write only, in reading the field will always be empty, even if set.
Time sync
Normally sensor asks for a time sync at every power on (uplink starting with 01) or once a week. If no
or wrong reply received it will retry after 1 hour.