A
PPENDIX
C
P
OINT
-
TO
-P
OINT
P
ROTOCOL
OVER
E
THERNET
(PPP
O
E)
6-84
Point-to-Point Protocol over Ethernet (PPPoE)
Point-to-Point Protocol over Ethernet (PPPoE): To set up a PPPoE connection, enter the Username, Password, and Service (name)
of the internet connection provided by your ISP. Click Next and the ERB300H/150H should connect to the internet successfully. A
PPPoE connection is usually from a DSL internet service.
1. Login: The username or e-mail address that the internet connection uses to access internet connectivity.
2. Password: The password that corresponds to the username or e-mail address used to connect to the internet in the PPPoE.
3. Service Name: The Service Name is optional. This is to signify the name of the Internet Service Provider.
4. MTU: Maximum Transmission Unit. It specifies the largest packet size permitted for internet transmission. The factory default
MTU size of Static IP is 1500. If you wish to manually change the MTU size, set it between 512 and 1500.
5. Point-to-Point Tunneling Protocol (PPTP)
To set up a PPTP connection, enter the type of WAN connection (Static IP or DHCP). After, depending on the type of WAN, follow the
instructions of DHCP or Static IP to fill out the corresponding information. Then, proceed to enter the Username, Password, Service,
and Connection ID of the PPTP internet connection. Once completed, click Next. Once configured, the internet connection will suc-
cessfully connect.
Layer 2 Tunneling Protocol (L2TP)
To set up an L2TP connection, enter the type of WAN connection (Static IP or DHCP). After, depending on the type of WAN, follow
the instructions of DHCP or Static IP to fill out the corresponding information. Then, proceed to enter the Username, Password, and
Service. Click next when completed. Once configured, the internet connection will successfully connect.
MTU: Maximum Transmission Unit. It specifies the largest packet size permitted for internet transmission. The factory default MTU
size of Static IP is 1500. If you wish to manually change the MTU size, set it between 512 and 1500.
Summary of Contents for X-TRA RANGE ERB150H
Page 14: ...Product Overview Chapter 1 ...
Page 21: ...Installation Chapter 2 ...
Page 24: ...EnGenius Quick Start Chapter 3 ...
Page 28: ...Installation Setup Wizard Chapter 4 ...
Page 36: ...Web Configuration Chapter 5 ...
Page 51: ...Basic Network Settings Chapter 6 ...
Page 130: ...BASIC NETWORK SETTINGS LOGOUT 6 79 6 8 Logout Click Logout to logout from the ERB300H ERB150H ...