Programming the Door-Propped-Open Warning and Delay Time:
If the keypad is connected to an optional magnetic contact or other door protection switch or
device, the keypad can be programmed to beep when a door has been propped open. This
prompts authorized users to close a door that was not closed properly or to investigate a door that
may have been deliberately propped open.
1.
Door-propped-open warning OFF (default):
81 0 #
2.
Door-propped-open warning ON:
81 ttt #
NOTE
:
•
TTT
represents the delay time, which can be set from 1 to 999 seconds.
•
The delay time provides time for a door to close normally before triggering the
door-propped-open warning.
•
The door-propped-open beeping will stop when the open door is closed.
Programming the Door Open Alarm and Timing:
When the keypad is connected to a magnetic contact or other door monitoring device, it can be
programmed to trigger the alarm output for 1 to 999 seconds if the door is opened. In this case, if
the alarm output is triggered, the output either automatically ends at the end of the programmed
time or when a user code or super user code is input for output #1.
NOTE
:
•
If programmed for door open alarm, the alarm will sound if the door is forced open without using
a user code and/or card. No alarm will sound if the door is opened with a user code and/or card.
•
The door open alarm and door-forced-open warning should not both be enabled, as the overlap
in timing could result in incorrect alarm output (see “Programming the
Door-Forced-Open Warning and Timing on page 26).
To Program:
1.
Door open alarm OFF (default):
91 0 #
2.
Door open alarm ON:
91 TTT #
NOTE
:
TTT
represents the alarm output time, which can be set from 1 to 999 seconds.