background image

- 4 - 

Fig. 6 – Dimensions (mm) 

 

 

For help or more information about this product or other fine access control products from 
SECO-LARM, please visit our website at www.enforcer.com.tw. 

 

Troubleshooting: 

1.  If the door does not release when the electric strike is activated — Open the door, and leave 

it open. Activate the electric strike to ensure if it is operating properly: 

a.  If the strike operates properly with the door open, the problem is probably a poor door 

latch, or the position of the electric strike needs to be adjusted by moving it or adding 
washers or shims. Test again. 

b.  If the strike does not operate properly with the door open, dismount the strike and check 

that the two wires are connected properly. Also ensure the wires are connected to   
12 VDC power supply. Test again. 

c.  Use a multimeter to test that the strike is receiving the proper voltage and amperage. If 

not, it may be necessary to use heavier gauge wires, or increase the output of the power 
supply. 

d.  If all the above tests do not locate the problem, then make sure the activation device 

(keypad, push-button switch, or whatever) is activating properly. 

2.  If the door does not lock properly when closed — This is probably a problem with the 

installation or with a bad door latch. In this case, it may be necessary to adjust the position of 
the strike, or possibly replace the latch. 

3.  For any other problems, replace the unit, and test again. The problem unit can also be 

substituted for a working unit in another door frame to see if it works there. 

 

Warranty:   

ENFORCER Electric Door Strikes are warranted against defects in material and workmanship 
while used in normal service for a period of one (1) year from the date of sale to the original 
customer. Our obligation is limited to the repair or replacement of any defective part if the unit is 
returned, transportation pre-paid, to SECO-LARM. 

 

Notice: 

The information and specifications printed in this manual are current at the time of publication. 
However, the SECO-LARM policy is one of continual development and improvement. For this 
reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is 
also not responsible for misprints or typographical errors. 
Copyright © 2011 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be 
reproduced or copied, in whole or in part, without the written permission of SECO-LARM. 

SECO-LARM

®

 U.S.A., Inc. 

1

6842 Millikan Avenue, Irvine, CA 92606

 

Website: www.seco-larm.com 

Tel: 800-662-0800 / 949-261-2999    Fax: 949-261-7326    E-mail: [email protected]

 

MiSD991xE1Q_1107.docx

PITBW1

 

- 1 - 

Installation Manual 

 

ENFORCER 

®

 

Electric Door Strikes 

SD-991A-E1Q Fail-Secure   

(Door locked with power disconnected) 

SD-991B-E1Q Fail-Safe   

(Door unlock with power disconnected) 

 

Features:

 

  Convert mortise lock sets to electronic 

access control locking systems. 

  Use on virtually any mortise door locking 

system. 

  Use with an optional digital keypad such as 

SECO-LARM’s SK-1011-SQ or SK-1131-SQ 
for keyless high security. 

  Reversible for right-hand or left-hand doors. 

  Shallow design for use with most doors. 

 

Stainless steel lip (keeper) for strength and 
long life.

 

  Non-polarized connection.    Wires can be

 

reversed. 

  Fail-Secure (SD-991A-E1Q) units are 

perfect for entrance door installations. 

  Fail-Safe (SD-991B-E1Q) units are perfect 

for emergency door and escape door 
installations. 

  Suitable for office-type applications. 

 

 

Specifications: 

 

Type 

Circuit type 

Input voltage 

Current Draw 

SD-991A-E1Q 

Fail-Secure 

N.O 

12 VDC 

400 mA 

SD-991B-E1Q 

Fail-Safe 

N.C 

12 VDC 

200 mA 

 

Installation 

1. Prepare door jamb as per drawing. 

 