12
2.7.14 Left Turn
Harsh turn events can be triggered when one of two available thresholds are exceeded as determined by
the accelerometer in milli-Gs (e.g., 0.75) for a defined period of time in seconds (e.g., 30 seconds).
The following AT command example sets the Left Turn accelerometer threshold 2 to .3Gs. If this threshold
is exceeded for 1 second, trigger the input event. This event will clear in 20 seconds when the acceleration
is below this threshold.
A
T$OBDALT=2,300,1,20
2.7.15 Up
Up accelerometer events can be triggered when the threshold is exceeded as determined by the
accelerometer in milli-Gs (e.g., 0.75) for a defined period of time in seconds (e.g., 30 seconds).
The following AT command example sets the Up accelerometer threshold to 1.2Gs. If this threshold is
exceeded for 1 second, trigger the input event. This event will clear in 30 seconds when the acceleration is
below this threshold.
A
T$OBDAUP=1,1200,1,30
2.7.16 Down
Down accelerometer events can be triggered when the threshold is exceeded as determined by the
accelerometer in milli-Gs (e.g., 0.75) for a defined period of time in seconds (e.g., 30 seconds).
The following AT command example sets the Down accelerometer threshold to .8Gs. If this threshold is
exceeded for 1 second, trigger the input event. This event will clear in 30 seconds when the acceleration is
below this threshold.
AT$OBDADN=1,800,1,30