9.3.10
Combustion Air Starvation
Venting system is dirty
. Refer to
Section 8: Maintenance
.
The flue is not properly installed.
Make certain the venting system meets the criteria in the
installation section of this manual as well as the venting system manufacturer’s instructions.
Inadequate fuel is used.
Remove the burn pot, make sure that all openings are clear and check
that no ash has filled the tube around the igniter. Refer to
Section 8: Maintenance
. Also, make
sure that recommended fuel is used (see
Section 5.2.1
Proper Fuel
) and settings are adjusted to
the type of pellets that are being used (see
Section 6.1.5
Adjusting the Combustion Level (Heat
Output)
).
Air intake channel is restricted.
Visually inspect the air intake channel that leads to the burn pot
for foreign material. Make sure that the air-intake shutter is functional and free of any
obstruction.
The combustion/exhaust blower failed.
Go to the troubleshooting page on the LCD screen and
test the combustion and the exhaust blowers independently (see
Section 9.2
Testing
Components
). If one of them does not function, make sure there is power and that the blowers
are properly connected. If they still don’t work, check fuse F4 and F5 on the control board. A
blown fuse will be darkened or will have a broken filament. If the fuses are in good condition, the
combustion or exhaust blower is probably defective; Replace the faulty part.
9.3.11
The LCD Touch Screen Does Not Lightup.
There is no electrical current going to the stove.
Check if the stove is connected and if there is
current in the wall outlet. Check if the F7 fuse is blown. Replace it if necessary.
TELCO wire is defective or not connected properly
. Convection blower, combustion blower,
exhaust blower and burn pot auger will start but the stove will beep continuously and the LCD
touch screen will remain black. Check connection and change wire, if necessary.
The temperature of the screen is below zero
. When the screen is exposed to temperatures too
cold, the liquid crystals may not function properly which causes a loss of communication. This
situation may occur in cases where the unit has arrived from outside by a carrier or is subjected to
a room temperature too low as in an unheated cottage or a very cold garage.
Summary of Contents for Cambridge EP00075
Page 64: ...64 Cambridge Pellet Stove Installation and Operation Manual 10 WIRING DIAGRAM ...
Page 73: ...Cambridge Pellet Stove Installation and Operation Manual 73 ...
Page 74: ...74 Cambridge Pellet Stove Installation and Operation Manual ...
Page 75: ...Cambridge Pellet Stove Installation and Operation Manual 75 ...
Page 76: ...76 Cambridge Pellet Stove Installation and Operation Manual ...
Page 77: ...Cambridge Pellet Stove Installation and Operation Manual 77 ...
Page 78: ...78 Cambridge Pellet Stove Installation and Operation Manual ...
Page 79: ...Cambridge Pellet Stove Installation and Operation Manual 79 ...