Power Supply..........................................................CR2 battery ×1pcs
RF Range....................................................Up to 100 feet line of sight
Z-Wave Frequency............................................................ 908.42MHz
Operation Temperature...........................................................32-104°F
DESCRIPTION
Battery-powered Z-Wave device for easy installation
Battery life approximately 1 year and Low battery detection
INSTALLATION
Provide Open/Close status to monitor door or window
1. The Door/Window Sensor consists of two parts: Sensor Unit and
2. Insert one CR2 battery to the Sensor Unit (noting the proper
3. Place Both Sensor Unit and Magnetic Unit by using screws and/or
4. The Sensor Unit and Magnetic Bar can be mounted vertically or
It is recommended to mount the Sensor Unit to Door/
The ZWN-BDS is a battery-powered and magnetic contact sensor
thermostat to a comfortable setting and notify you when the door
or window is opened and the sensor is armed.
Operation Gap................................................................Up to 1/2 inch
that wirelessly controls lights and appliances throughout your
house. When magnetic contact is broken, such as a door or
window being opened, the ZWN-BDS transmits Open/Close status
Magnetic Bar.
orientation).
adhesive pad.
horizontally.
Window frame and Magnetic Bar to the Door/Window, no more than
1/2 inch apart. Ideally, the Door/Window frame should be wooden
ADVANCED FEATURE
Sensor Unit
Magnetic Bar
Program Button
Right
Screws and Adhesive Pad Mounting
Status LED
Adding to Z-Wave network
Note: If the Door/Window sensor is not added in Z-Wave
applied or program button pressed.
network, status LED will blink three times when power
1. Set a Z-Wave controller into deleting mode.
Deleting
Association
To complete Z-Wave association, please refer to your controller's
manual. Each controller has its own association method. If your
controller needs sensor to wake up, please press and hold the
program button for 2 seconds, release the button when status
OPERATION
At the back of Door/Window Sensor, there is a program button which
is used to do adding/deleting and association. Also it can be used as a
1. Set a Z-Wave controller into adding mode.
2. Press and release the program button located at the back of Door/
Adding
3. Status LED will stay solid for 10 seconds and turn off when succeeds.
Window sensor to add it into your Z-Wave network and send
Node Information Frame.
4. If the LED never light on and adding mode times out, then repeat the
adding process again and delete it if necessary.
LED turns off, the ZWN-BDS will wake up manually.
tamper alarm button, and wake up Door/Window sensor manually.
For indoor use only
Support Z-Wave associations, sending commands up to 5
associated Z-Wave devices
battery life. If the Door/Window sensor
_NO_
up manually: press and hold
back to sleep to conserve
receives command WAKE_UP
The Door/Window Sensor can be woken
the program button for one second, when
release the button it will
to associated devices.
Wakeup command class
The Door/Window sensor will send a wakeup notification command if
it has been added into a Z-Wave network. The Door/Window Sensor
will wake up periodically(default is 30 minutes) as desired depending
wakeup notification command unless configured for another time interval.
you set from wakeup command class and resend the
will stay awake for 10 seconds and then go
on time interval
The Door/Window sensor
send broadcast wakeup notification or singlecast
It will also go to sleep when
hasn't been added to any network, it stays awake only for 1 second.
MORE_NOTIFICATION_V2.
wakeup notification
to the gateway and can do things like turning on lights, setting the
because of metal surface could sometime cause signal interference.
2. Press and release the program button located at the back of Door/
Window sensor to delete it into your Z-Wave network and remove
Node Information Frame.
3. Status LED will blink 3 times after press the program button, that
means it is not in any Z-Wave network.