background image

INSTALLATION

NSTRUCTIONS

WARRANTY INFORMATION

© 2016 Enerwave Home Automation ● WWW.ENERWAVEAUTOMATION.COM ● CA, USA

Model: 

ZW

15R

-N

Wireless Home Automation Control Device

 

15A Tamper Resistant Duplex Receptacle

with Interchangeable Face Cover

020

9

1600

46-0

3

INSTALLING

 Z-WAVE

 RECEPTACLE

S

LOCATIONS

Installation of Z-Wave devices instantly increases the functionality, efficiency, and value of your home. The more devices you install, the more efficient your house will be. The most effective 

locations to install Z-Wave devices are in the Living Room, Bedrooms, Kitchens, Family Rooms, Guest Rooms, and Entertainment Rooms.
This device complies with the Z-Wave standard of open-air, line of sight transmission distances of 100 feet. Actual performance in a home depends  on the numbers of walls between the remote 

controller and the destination device, the type of construction and the number of Z-Wave enabled devices installed in the control network. Z-Wave devices act as signal repeaters ONLY after 

they are "Included" on the network.

If you have trouble identifying the wires, 

STOP

 and consult with an electrician.

DO NOT REVERSE ANY WIRES. DOING SO WILL VOID YOUR WARRANTY AND 

THE RECEPTACLE WILL SHORT CIRCUIT.

Step 1.

 Identify all your wires

.

 Label the wires or draw a diagram of existing wires.

Step 2. 

Insert wires into the terminal holes on the back, then tighten the terminal screws.

Connect the BLACK wire to the HOT terminal (brass screw).

Connect the WHITE wire to the NEUTRAL terminal (silver screw).

Connect the GREEN or BARE wire to the GROUND terminal (green screw). 

REQUIREMENTS

Z-Wave devices requires a connection to a compatible hub. Once the device is properly added to the 

H

ub, it can be 

managed and customized to your needs. Please visit www.enerwaveautomation.com for a list of compatible hubs

.

This device is warranted to be free of material and workmanship defects for 2 years from the date of 

purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty 

claim. ALL claims must be verified and approved by 

Enerwave

, Inc. Warranties from other 

Enerwave

 

products may vary. This warranty is nontransferable and does not cover normal wear and tear or any 

malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper 

installation.  To the fullest extent permitted by the applicable state law, 

Enerwave

 shall not be liable to the 

purchaser or end user customer of 

Enerwave

 products for direct, indirect, incidental, or consequential 

damages even if 

Enerwave

  has been advised of the possibility of such damages. 

Enerwave

’ total liability 

under this or any other warranty, express or implied, is limited to repair, replacement or refund.  Repair, 

replacement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.

DESCRIPTION

The 

ZW15R-N

 is a technologically advanced Tamper Resistant Duplex Receptacle. The 

top receptacle is "always ON" and the bottom receptacle is Z-Wave controlled. For the 

advanced users, the functions are programmable for setting scenes, associations and 

scheduling events.

FEATURES

Replaces standard 120VAC receptacles

Wireless Z-Wave technology creates a mesh network for command and control 

interoperability with other Z-Wave compliant controllers and devices

Manual and remote on/off control of any connected load

Tamper-resistant (TR) receptacles keep you and your family safe

Reduce energy consumption and enjoy wireless home automation 

Over Current and Short Circuit protection up to 15A 

SPECIFICATIONS

Voltage.............................................................................................120VAC, 60Hz

Incandescent................................................................................................1000W

Ballast.........................................................................................................1200VA

Resistive..............................................................................................1800W(15A)

Motor............................................................................................................ 1/2 HP

Z-Wave Frequency.............................................................................. 908.42 MHz

Operating Temperature........................................................................... 32-104° F

FCC  COMPLIANCE

 STATEMENT

FCC Grant of Equipment Authorizations of this device and transmitters installed in this device can be found at FCC website by entering the FCC ID number on the device.

Caution:

 Changes or modifications not expressly approved by the part responsible for compliance could void the user’s right to operate the equipment.  

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept 

any interference received, including interference that may cause undesired operation of the device. 
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable 

protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause 

harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of 

the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help. 

WARNING

Turn the POWER OFF at the circuit breaker before installing the 

Receptacle

Read and understand these instructions before installing. This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a qualified electrician performs this installation. Make sure to turn off the circuit breaker or fuse(s) 

and make sure power is off before wiring the device. Exercise extreme caution when using Z-Wave devices to control appliances. Operation of the Z-Wave device may be in a different room than the controlled appliance so an unintentional activation may occur if the wrong button on 

the remote is pressed. Z-Wave devices can be automatically powered on by programmed events. Unattended or unintentional operation could result in hazardous conditions. Z-Wave enabled devices should never be used to supply power to, control

,

 or monitor medical and/or life 

support equipment. 

Use copper wires only.

NOTES

This Z-Wave device must be configured and added to a Z-Wave network 

before it can be operated and controlled from a smart device. Follow the 

instructions on the next page and the manual(s) associated with the Hub 

for configuration.