INSTALLATION INSTRUCTIONS
•
•
•
•
Control your lights with your smart devices without the need of any
hub
Easy to configure, easy to use
free s
mart App
by Enerwave
Save energy by automating the ON/OFF times or using the
schedule
Works with
Amazon Alexa, Google Assistant
through the Tuya App
SPECIFICATIONS
Model: WF
500D
Wi-Fi
Smart
Dimmer
Switch
FEATURES
Protocol
...........................................................
..............
........…
...IEEE 802.1b/g/n
Wireless Type
.........................
.......................
.....
............
.
.........................
.
2.4GHz
Operatin
g
Temperature....................................
..
...................
.
32°-1
04
°F
(0°-40°C)
System Requirements
............................
....Android 4.1 or higher/ iOS 8 or higher
•
Secure 2.4GHz
Wi-Fi
network
connection
•
Smart Device such as a Smart Phone or Tablet with an operating
system of Android version 4.1 or higher or iOS 8 or higher
•
Installation of the
ENERWAVE
Smart App on the Smart Device
•
Neutral wire required
REQUIREMENTS
Voltage
.................................
.................................
.........................
120VAC, 60Hz
WARNING
Turn the POWER OFF at the circuit breaker before installing the
Smart Dimmer
Read and understand these instructions before installing. This device
is intended for installation in accordance with the National Electric
Code and local regulations. It is recommended that a
qualified electrician performs this installation.
Use copper wire only
Only Use Wires with Minimum Temperature Rating 75°C (167°F)
WIRING DIRECTIONS
First, find out if you will be controlling the lights from one location or multiple locations.
Next, identify all the wires. Once you've identified the wires, follow the diagram below
for wiring.
LED
/ Self Ballasted
..............................
.........
......................................
2A (
150W
)
RETROFIT WIRING
NEUTRAL
NEUTRAL
LOAD
TRAVELER
LOAD
HOT
GROUND
DIAGRAM 2
WF
500D
S
WITCH
O
NE
COMMON 3-WAY WIRING
LOAD
NEUTRAL
NEUTRAL
TRAVELER A
TRAVELER B
HOT
LOAD
SWITCH
ONE
SWITCH
TWO
DIAGRAM 1
AIR-GAP SWITCH FUNCTION
FCC COMPLIANCE STATEMENT
FCC Grant of Equipment Authorizations of this device and transmitters installed in this device can be found
at FCC website by entering the FCC ID number on the device.
Caution:
Changes or modifications not expressly approved by the part responsible for compliance could
void the user’s right to operate the equipment. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation of the device.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
1
2
3
GROUND
Step 1.
Identify all your wires (DIAGRAM 1). Label the wires or draw a diagram of existing wires.
Step 2.
Convert the TRAVELER B wire to the LOAD wire. To do so,
t
ake the LOAD wire and
TRAVELER B wires off SWITCH 1 and connect them together with a wire
cap
(DIAGRAM 2).
Step 3.
Connect the other end of the TRAVELER B wire to the LOAD terminal on
the
WF
500D
Step 4.
Connect the NEUTRAL wire to
both switches.
Step 5.
Connect the TRAVELER A wire
from the WF
500D
to
one of the terminals
on
the 3-way switch.
Step 6.
Connect the HOT wire to the HOT terminal on the WF
500D
.
Step 7.
Connect the GROUND wire
s
to the GROUND terminals on both switches
.
Incandescent
..................................
.......................
................
.......
....
...........
.600W
RETROFIT WIRING
with WF3K
NEUTRAL
NEUTRAL
LOAD
TRAVELER
LOAD
HOT
GROUND
DIAGRAM
3
WF
500D
WF
3K
•
Single Pole or 3-
W
ay compatible
•
Compatible with dimmable LED, self-ballasted bulbs,
incandescent
and halogen bulbs. Do NOT use CFL bulbs
The Air-Gap Switch on the bottom of
the smart dimmer is designed to
keep the circuit open so no electricity
reaches the load as a safety feature
when replacing
dimmable
bulbs. To
pair the smart dimmer with the
Enerwave App and to operate the
connected load normally,
p
lease
verify that the Air-Gap switch is all
the way to the right position.