22
FAILURE SEARCH AND TROUBLE SHOOTING
SUPPLY AIR TOO COLD
Reason
Action
* Supply air temperature set too low
Set higher value on the thermostat
* The exhaust fan has stopped
Contact a service man
* The exhaust air filter is blocked
Change the exhaust air filter
* Exhaust air valves settings incorrect
Contact a service man
* Heat insulation of ducts inadequate
Check the insulation thickness of the
supply and exhaust air ducts and
add insulation if needed.
REDUCED AIR FLOW
Reason
Action
* Filters are blocked
Change the filters
* Speed selector switch of the fans Select higher speed
has been turned down
* Blockage in the fresh air grille
Clean the outer grille
* Fan wings dirty
Clean the fans
INCREASED OPERATING SOUND LEVEL
Reason
Action
* Filters blocked
Change the filters
* Outer grilles are blocked
Clean the outer grille
* Fan bearings faulty
Change bearings / contact service
* Fan wings dirty
Clean the fans