INSTALLATION
The unit should be installed on the wall or in the ceiling of a warm or half warm room (over
+5 °C). The location can be for example a scullery or utility room, however, not the garage
(a separate fire area). The unit must be drained. There is a drain outlet (1/4” inner thread)
in the bottom of the unit. At the time of delivery, the outlet is plugged.
Phases of installation (installation on the wall):
A1 Mark and cut the holes in the ceiling.
B1 Draw the ducts through the holes to the required height. The gaps between duct and
steam barrier are then sealed, with for instance ventilation tape.
C1 Fasten the wall bracket with screws to the wall (picture C1). Install an insulation
board between the wall and the unit to reduce the transfer of machine noise or
vibration. The insulation also keeps the unit in a vertical position.
D1 Lift the unit onto the bracket and fasten to the wall with two screws from inside the
unit (pictures D1).
E1 Connect the ducts to the tubes on top of the unit. It is recommended that silencers be
installed to the exhaust air and supply air ducts. Silencers, see page 7.
F1 Drain the unit. Connect a pipe between the drain outlet (¼” inside thread) and the
nearest floor drain or water trap of a sink. Connecting the unit directly into the
sewage system is not allowed. The drainage must always be done through a water
trap, otherwise the condense water will not be removed when the fans are on.
Picture C1. The wall bracket
Summary of Contents for Fenix 120
Page 12: ...12 Pictures D1 Securing the fastening with two screws...
Page 13: ...13 Fenix dimension drawing wall mounting left handed...
Page 15: ...15 Fenix dimension drawing ceiling mounting left handed...
Page 23: ...23 T E C H N I C A L D A T A CHARACTERISTICS FENIX 60...
Page 24: ...24 FAN EFFICIENCY RATES FENIX 60...
Page 25: ...25 CHARACTERISTICS FENIX 85...
Page 26: ...26 FAN EFFICIENCY RATES FENIX 85...
Page 27: ...27 CHARACTERISTICS FENIX 120...
Page 28: ...28 FAN EFFICIENCY RATES FENIX 120...
Page 30: ...30 W I R I N G D I A G R A M S WIRING DIAGRAM...