Manual
Operation Manual for
ZeMa Single Cells
Prepared on: 23-11-2022
Prepared by: GBA
Released on: 04.01.2023
Released by: -
Revised on: -
Index: _-
Distributed to: customer (public)
Pages: 26/35
This document is uncontrolled when printed. For the most current and official copy, check the server.
Rail Engineering
Tel. +49 (0) 2331/372 591
Dieckstrasse 42
Fax +49 (0) 2331/372 804
DE-58089 Hagen
www.enersys.com
8.6.4 Mechanical damage caused by force (E.g. accidents)
Falling, a strong shock or contact with aggressive chemicals, can demolish the case of
the cells, conducting electrolyte can escape and internal short circuit can occur.
Caution risk of short circuit!
All
exposed metal parts
of the battery cells are hot.
Danger of injury by electric shock or short circuit.
Touch the battery only on the plastic surfaces.
Do not place any foreign objects or tools on the battery.
Use protective glasses and clothes!
Protect the eyes
if you come near the battery,
liquids and explosive gases can cause blindness and damage
While
working on batteries
observe the accident prevention regulations,
as well as EN 62485-2 and -3 and EN 50110-1.
If the damaged battery is connected to a circuit: Disconnect the battery with the installed
electrical isolation device from the load circuit. (Battery switch; when de-energized:
Emergency, connector battery connector, possibly cell connectors)
In case of accidents neutralize the leaking electrolyte with lime. The remains are to be
environmentally friendly disposed of and by no means can the material be poured into the
waste.
Consult the leaflet “Instructions for the Safe Handling of Rail Batteries”, for further
questions contact our customer service!
If any Acid splashes into eyes or onto skin rinse under clear running water. After contact
with eyes seek immediate advice from a medical doctor, please also contact your doctor
after serious skin contact.
Caution!
Lead-acid batteries are
very heavy!
Pay attention to safe installation and use only suitable handling
equipment and hoists.
Special care is required when the battery tray has cracks or mechanical damages.