background image

• 9 •

Initial Percent Calculation:

 When a battery % is calculated for the first time after 

connecting a battery, the digital display will show dashes (“- - -“ or “- -“ depending on the 

model) for a period as long as several seconds while the tester analyzes the battery.

General Charging Notes
Relay

 (All Models except OMAX-25A-1B)

The charger is equipped with a relay that turns the charge current on and off to the battery. 

It is normal to occasionally hear a clicking sound when the relay is turned on or off.

Fan

 (Model OMAX-25A-1B)

It is normal for the fan to be on while the charger is charging (as long as the voltage 

is above 9V). The fan is normally off at other times but may cycle on and off due to 

temperature or other conditions (see Over-temperature Protection). Keep the area near 

the charger clear of obstructions to allow the fan to operate efficiently.

Over-temperature Protection

 (All Models except OMAX-6A-1B and OMAX-12A-1B)

The charger is equipped with an internal thermocouple that monitors the temperature. 

If the temperature rises above a preset level the charge current will be reduced to allow 

the charger to cool. If the temperature cannot be reduced at the lower charge rate the 

charge current will be turned off until the temperature is down to a normal level. The 

charger will then continue where it left off. For best results do not place the charger in 

direct sunlight or enclosed spaces with high temperatures.

13.  MAINTENANCE INSTRUCTIONS

13.1 

After use and before performing maintenance, unplug and disconnect the battery 

charger (see sections 6, 7 and 8).

13.2 

Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery clips, 

cords, and the charger case.

13.3 

Ensure that all of the charger components are in place and in good working condition, 

for example, the plastic boots on the battery clips.

13.4 

Servicing does not require opening the unit, as there are no user-serviceable parts.

13.5 

All other servicing should be performed by qualified service personnel.

14.  MOVING AND STORAGE INSTRUCTIONS

14.1 

Store the charger unplugged, in an upright position. The cord will still conduct electricity 

until it is unplugged from the outlet. 

14.2 

Store inside, in a cool, dry place (unless you’re using an on-board Marine Charger).

14.3 

Do not store the clips on the handle, clipped together, on or around metal, or clipped  

to cables. 

14.4 

If the charger is moved around the shop or transported to another location, take care to 

avoid/prevent damage to the cords, clips and charger. Failure to do so could result in 

personal injury or property damage.

Summary of Contents for Odyssey Ultimizer OMAX-12A-1B

Page 1: ...th Quick Disconnect Model OMAX 12A 1B Single Bank Charger Model OMAX 25A 1B Single Bank Charger Model OMAX 50A 1B Single Bank Charger Model OMAX 40AS 3B Three Bank Sequencing Charger Model OMAX 50AS 3...

Page 2: ...arger to rain or snow 1 3 Use only recommended attachments Use of an attachment not recommended or sold by Schumacher Electric Corporation may result in a risk of fire electric shock or injury to pers...

Page 3: ...nces These batteries may burst and cause injury to persons and damage to property 2 5 NEVER charge a frozen battery 2 6 NEVER overcharge a battery 2 7 Consider having someone nearby to come to your ai...

Page 4: ...THE RISK OF A SPARK NEAR THE BATTERY 6 1 Position the AC and DC cables to reduce the risk of damage by the hood door and moving or hot engine parts NOTE If it is necessary to close the hood during the...

Page 5: ...t specially designed for marine use 8 AC POWER CORD CONNECTIONS RISK OF ELECTRIC SHOCK OR FIRE 8 1 This battery charger is for use on a nominal 120 volt circuit The plug must be plugged into an outlet...

Page 6: ...e of the following settings On Indicates the charger is in charge mode Off Indicates the charger is in test mode Output Button Model OMAX 50A 1B Press this button to set the charger to one of the foll...

Page 7: ...ed to charge up to and including three 12V batteries in sequence When charging in sequence only one of the three banks is on at a time Every few minutes the charger will alternate which output is on a...

Page 8: ...e of charge The charger does not have a built in load tester As such a recently charged battery could have a temporarily high voltage due to what is known as surface charge The voltage of such a batte...

Page 9: ...harge current will be turned off until the temperature is down to a normal level The charger will then continue where it left off For best results do not place the charger in direct sunlight or enclos...

Page 10: ...due to a very large battery or a bank of batteries requiring more power than the charger can deliver in 24 hours Battery may be defective Reset the charger by unplugging the charger from the 120V AC...

Page 11: ...nnected and the charger is on but is not charging The battery is connected to a bank that is set to TEST Mode Two or more batteries are being charged in sequence Press the appropriate BANK button to s...

Page 12: ...arger It is both dangerous and damaging to a battery to force higher amperage into it than it can effectively use in recharging 16 3 When an UNKNOWN OPERATING PROBLEM arises please read the complete m...

Page 13: ...thorized retailer Manufacturer makes no other warranties including but not limited to express implied or statutory warranties including without limitation any implied warranty of merchantability or im...

Page 14: ...14...

Page 15: ...ic Corporation 801 Business Center Drive Mount Prospect IL 60056 2179 Name_______________________________________________________________ Street Address________________________________________________...

Reviews: