SAE and DIN Posts
These are posts in the shape of truncated 
cones with slightly different diameters to  
indicate polarity. The positive post is larger 
than the negative post.

PLEASE REFER TO THE ILLUSTRATIONS BELOW FOR TERMINAL DETAILS.

Stud Posts
These terminals have a stud post with various 
threads as specified for each battery

Dual Terminal Posts
These terminals have a stud post and SAE 
post.

Female Thread
This type of terminal consists of a female thread 
which can take various adapters/terminals with 
an M6 or M4 thread as specified for each battery. 
Please refer to the product label for torque  
specifications.

SAE 3/8 -16” Female Thread
This is an SAE post which can be installed on female 
M6 terminals. The SAE post has a 3/8-16” female 
threaded post.

Side 3/8 -16” Female Thread
Side terminals are sometimes supplied in addition 
to top terminals. In this case, top terminals allow the 
fixing of other connections to power accessories. 

Front Terminal Adapters
These connect to female inserts on the top 
of the battery to allow for connections on the 
front of the battery. 

POSITIVE

NEGATIVE

1:9

Taper

SAE Terminals

DIN

POSITIVE MARINE STUD

NEGATIVE MARINE STUD

POSITIVE SAE

 

TERMINAL

NEGATIVE SAE

 

TERMINAL

M10

3/8-16 FEMALE 

THREAD

BRASS SAE 

TERMINAL (SEE 

SAE DIAGRAM FOR 

DETAILS)

BATTERY  

TERMINAL  

(FEMALE M6)

SIDE TERMINAL

SIDE TERMINAL

3/8-16 UNC-2B

8.6mm DEEP

21.6mm

28.5m m

M6 Thread

3/8-16 THREAD

M6 FEMALE 

THREAD

M6 FEMALE 

THREAD

6

Summary of Contents for NSB-AGM

Page 1: ...AGM2 Technical Manual...

Page 2: ...specifications 7 V Technical details 7 A Operating temperature range 7 B Understanding state of charge 8 C Storage and self discharge 8 D Battery life expectations 9 E Float applications 9 F Charging...

Page 3: ...designed to provide relatively low current for a long duration of time cannot provide the high current bursts that are needed for starting applications AGM2 batteries can do both tasks making them an...

Page 4: ...Be sure to wear the appropriate personal protective equipment 2 Note the orientation of the existing battery s positive and negative terminals 3 Disconnect the cables negative first from the old batte...

Page 5: ...e negative terminals are connected In this configuration the system voltage is the voltage of one battery Parallel systems are wired as shown below C BATTERY CABLING Since battery cables are the conne...

Page 6: ...for torque specifications SAE 3 8 16 Female Thread This is an SAE post which can be installed on female M6 terminals The SAE post has a 3 8 16 female threaded post Side 3 8 16 Female Thread Side termi...

Page 7: ...model Terminal Type Details Maximum Torque in pounds Maximum Torque Nm Stud 3 8 16 HD All G31 Marine and 8D 200 22 6 Stud 3 8 16 ODS AGM6M 100 11 3 Stud 5 16 18 All Marine 100 11 3 Side Terminal 3 8...

Page 8: ...oses charge depends on the temperature The warmer the temperature the shorter the storage time before a freshening charge is required Cooler temperatures slow down the rate of self discharge A good ru...

Page 9: ...ATIONS Batteries that are primarily used as a source of backup or emergency power are not frequently cycled The life of these types of applications is referred to as float life Emergency lighting secu...

Page 10: ...rent should never be less than 10 of the battery s C10 rating Voltages higher than 15 0 volts will cause irreversible damage to the battery Please refer to Figure 2 below for a graphical representatio...

Page 11: ...e battery For batteries used in starting applications the alternator can be used to recharge the battery after jump starting the battery to start the vehicle For batteries not used in starting applica...

Page 12: ...charge For all methods the battery should be as fully charged before testing Following are details related to each test method RECOMMENDATION Testing should be completed on a clean main battery termin...

Page 13: ...der normal operating conditions This means that there should be minimal corrosion of terminals or any part of the surrounding area It also means there is no need to ever add water to the batteries Ope...

Page 14: ...te of discharge will deliver 10A for 10 hours before the terminal voltage drops to a standard value such as 10 5V for a 12V battery Does mishandling the battery void the warranty The warranty applies...

Page 15: ...varies based on the battery type Refer to table 3 on page 7 for details Is the battery ruined if it is dropped It is possible to damage the internal connections as well as the external container leadi...

Page 16: ...Switzerland EnerSys Asia 152 Beach Road 11 08 Gateway East Building Singapore 189721 Tel 65 6416 4800 2021 EnerSys All rights reserved Trademarks and logos are the property of EnerSys and its affiliat...

Reviews: