ENGLISH

SAFETY INSTRUCTIONS

GOALS OF THIS MANUAL

This manual is aimed at any authorized personnel wanting to
use a 3-phase

LifeSpeed iQ

TM

charger to recharge lead acid

motive power batteries (vented, NexSys

®

, Gel or Water Less

®

/

Water Less

®

20 ranges).

This manual contains information on:

Charger functionality.

Use and setting of charger parameters.

Technical specifications of the LifeSpeed iQ chargers.

EnerSys

®

intends to provide clear and simple information

in this manual, and assumes no responsibility for misunder-
standing or improper interpretation of the information.
The owner of the equipment is required to preserve this
manual during the life of the equipment and to transfer said
manual to any subsequent purchaser.

WARRANTY

Warranty is offered by the

manufacturer based on local

regulations. Please contact your local distributor for further
information.

RECOMMENDATIONS

Recommendations for safe operation

This manual should be carefully read, prior to using the equip-
ment,

by

anyone

intending

to

use

the

charger.

LifeSpeed iQ:

Must not have its air circulation impaired in any way,
primarily around the air inlet areas.

Dust accumulation must be removed every 12 months.

Must be used within its protection norms, and never
be directly in contact with water.

Must be used only within the temperature range
specified in the technical specifications.

Internal connection torques must be checked once a year.

Must not be installed on a surface subject to high
vibration levels (proximity of motors, compressors, etc.).

Must not be installed close to the batteries in order to
avoid any gassing that could damage it prematurely.

Must not be installed in arduous environments such as:
• Harbour applications (saline environment)
• Close to cold stores
• External locations with exposure to wind and rain

This appliance is not intended for use by persons (including
children) with reduced physical and mental capacities, who
are not experienced in their use, unless instructed to do so by
a person responsible for their safety.

Operator safety

Take all necessary precautions when the equipment will
be used in areas where there is the possible risk of an
accident occurring. Ensure appropriate ventilation according
to standard EN 62485-3 to allow any gases released to esca-
pe. Never disconnect the battery while it is being charged.

General warnings

Requirements for use:

The equipment must be properly grounded (earthed).

The input voltage must match the charger requirements.

The

battery

voltage

must

match

the

charger’s

capabilities.

The battery capacity is within the charger’s range.

ELECTRICAL SAFETY

Safety regulations and requirements must be observed.

Safety devices installed on the electrical supply to the
chargers must be of the proper type and rating. It is
important to ensure that only fuses of the proper
capacity should be used if they need to be replaced.

The equipment must be totally disconnected from all power
sources (mains supply and battery) before it can be opened
for inspection or servicing. The battery can only be discon-

nected after the charge has been stopped by pushing the
Stop/Start button. Access to the inside of the charger should
be restricted to authorized maintenance personnel.

Please consult a qualified factory representative about any
problems or questions related to the installation of this unit.

LIMITS OF USE

This charger is designed to be used in a sheltered area.
It is designed exclusively to recharge lead batteries in an
industrial environment.

PRODUCT RECYCLING - DESTRUCTION

When this charger becomes obsolete, it can be recycled
or destroyed by authorized facilities. Local regulations will
prevail and must be followed.

MODIFICATIONS AND IMPROVEMENTS

EnerSys reserves the right, at any time, to modify or
improve its products, without any obligation to update
this product or this manual accordingly.

The customer is not permitted to modify the product from its
original design and configuration (e.g. fitting additional
modules).
Any changes made by the customer could affect the
product performance and invalidate the warranty.

RECEIVING - STORAGE

Upon receipt, please inspect visually the exterior of the
charger for any physical damage. If necessary, proceed
within 24 hours with the usual claims procedure with the
transport company.

If the charger is to be stored before use, it should remain
in the original packaging, carefully closed. Store in a clean,
dry area at a moderate temperature (0 °C to +40 °C). If the
equipment is stored at a temperature below 15°C, it must
be gradually (24 hours) restored to operating temperature
before use, to prevent the risk of condensation that could
cause electrical faults and short-circuits.

INFORMATION PLATE

Located on either side of the charger.

EU DECLARATION

EnerSys hereby declares that the chargers in the
Lifespeed iQ range covered by this declaration
conform to the descriptions laid down in:

European Directive 2014/35/EU:

Low Voltage Directive
European Standard:
EN60950-1: 2006+A11:2009+A12:2011+A1:2010+ A2:2013

European Directive 2014/30/EU:

Electromagnetic Compatibility
European Standards:
- EN61000-6-2: 2006
- EN61000-6-4: 2007+A1: 2011

European Directive 2011/65/EU:

ROHS

European Directive 2013/35/EU:

Electromagnetic fields
European Standards:
- EN62311: Oct 2008

Note: DC cables of the charger emit low power magnetic
fields in their surroundings (<5cm). Even if emissions are
below the standard limits, people bearing medical implants
should avoid operating close to the charger during recharge.

Safety and use instructions LifeSpeed iQ

TM

- 3-phase chargers

Summary of Contents for HAWKER LifeSpeed iQ

Page 1: ...talled on the electrical supply to the chargers must be of the proper type and rating It is important to ensure that only fuses of the proper capacity should be used if they need to be replaced The equipment must be totally disconnected from all power sources mains supply and battery before it can be opened for inspection or servicing The battery can only be discon nected after the charge has been...

Page 2: ...alisation charge Access to a sub menu Access to the menus press 3 seconds Close the window UNPACKING The charger is delivered with the following 2 m AC mains cable 3 m DC battery cable This technical manual MECHANICAL INSTALLATION The charger is intended to be wall mounted only 3 bay cabi net or floor standing and must be installed in the vertical orientation The distance between 2 adjacent charge...

Page 3: ...le pump fault or DF4 2 Alternating display of battery voltage voltage per cell Ah restored charging time remaining charging time percentage of battery charge 3 4 Charging current 5 Programmed charging Detected charging profile profile 6 Various information can be displayed equalisation symbol required at the end of charge USB connection symbol Wi iQ link symbol possible battery default DF4 See mor...

Page 4: ...ion charge is indicated by the message EQUAL During the equalisation charge the charger displays the current ref 4 and alternating the battery voltage voltage per cell remaining time ref 2 2 The battery will be available as soon as the screen becomes green Automatic start If the equalisation charge has been programmed Configuration Equalisation menu the equalisation charge is initiated automatical...

Page 5: ...for Use Critical battery temperature One or more modules are not working correctly One or more mo dules are not the correct specifica tion Looking for presence of Wi iQ Set the link Wi iQ Charger Low electrolyte level Default of balance voltage detected by the Wi iQ Too high battery temperature Preventive mainte nance indicator The Wi iQ on the battery is not func tioning correctly The charger wil...

Reviews: