This manual is aimed at any authorized personnel wanting to use a Life On

TM

charger to recharge lead acid motive

power batteries (vented, Hawker

®

XFC

TM

, gel and AGM).

This manual contains information on:
• Charger functionality.
• Use and setting of charger parameters.
• Technical specifications of the Life On chargers.

EnerSys

®

intends to provide clear and simple information in this manual, and assumes no responsibility for 

misunderstanding or improper interpretation of the information. The owner of the equipment is required to preserve
this manual during the life of the equipment and to transfer said manual to any subsequent purchaser.

WARRANTY

Recommendations for safe operation

This manual should be carefully read, prior to using the
equipment, by anyone intending to use the charger.

The Life On:
• 

Must not have its air circulation impaired in any way,
primarily around the air inlet areas.

• 

Dust accumulation must be removed every 12 months.

• 

Must be used within its protection norms, and never be
directly in contact with water.

• 

Internal connection torques must be checked once a
year.

• 

Must not be installed on a surface subject to high vibra-
tion levels (proximity of motors, compressors, etc.).

• 

Must not be installed close to the batteries in order to
avoid any gassing that could damage it prematurely.

• 

Must not be installed in arduous environments such as:

• Harbour applications (saline environment)
• Close to cold stores
• External locations with exposure to wind and rain

Operator safety

All proper precautions must be observed when 
the equipment is used in areas where accidents are
possible.

Ensure proper ventilation when the charger is 
used with lead-acid batteries, due to gassing. 

Never disconnect the battery during the charging 
process.

General warnings

Requirements for use:
• 

The equipment must be properly grounded (earthed).

• 

The input voltage must match the charger 
requirements.

• 

The battery voltage must match the charger’s 
capabilities.

• 

The battery capacity is within the charger’s range.

• 

The equipment must not charge a frozen battery.

1. ELECTRICAL SAFETY

Safety regulations and requirements must be observed.
Safety devices installed on the electrical supply to the
chargers must be of the proper type and rating. It is impor-
tant to ensure that only fuses of the proper capacity should
be used if they need to be replaced. The equipment must be
totally disconnected from all power sources (mains supply
and battery) before it can be opened for inspection or 
servicing. The battery can only be disconnected after the
charge has been stopped by pushing the Stop/Start button.
Access to the inside of the charger should be restricted to
authorized maintenance personnel.

Please consult a qualified factory representative about any
problems or questions related to the installation of this
unit.

2. LIMITS OF USE

This charger is designed to be used in a sheltered area. 
It is designed exclusively to recharge lead batteries in an
industrial environment.

3. PRODUCT RECYCLING - DESTRUCTION

When this charger becomes obsolete, it can be recycled or
destroyed by authorized facilities. Local regulations will 
prevail and must be followed.

4. MODIFICATIONS AND IMPROVEMENTS

EnerSys reserves the right, at any time, to modify or 
improve its products, without any obligation to update
this product or this manual accordingly. The customer is not
permitted to modify the product from its original design and
configuration.
Any changes made by the customer could affect the product
performance and invalidate the warranty.

5. RECEIVING - STORAGE

Upon receipt, please inspect visually the exterior of the 
charger for any physical damage. If necessary, proceed
within 24 hours with the usual claims procedure with the
transport company. If the charger is to be stored before use,
it should remain in the original packaging, carefully closed.
Store in a clean, dry area at a moderate temperature (0 °C to
+40 °C). If the equipment is stored at a temperature below
15 °C, it must be gradually (24 hours) restored to operating
temperature before use, to prevent the risk of condensation
that could cause electrical faults and short-circuits.