Wi-iQ – the electronic device – will provide indications
according to the table below.
Tricolour LEd
Green blinking = hardware OK
Blue rapid blinking = wireless identification
Red blinking = temperature warning > 55° C
Blue LEd
Rapid blinking = wireless identification
Slow blinking = voltage balance warning
OFF - Flashing = electrolyte level is OK
Light is constantly on =
electrolyte level is low - please top up
The Wi-iQ is the electronic device that communicates
wirelessly to download the battery key information for better
diagnostics & service. The device is fitted to a main DC cable
on the battery to monitor and record data of current, voltage,
temperature and electrolyte level (via optional external
sensor). The LEDs on the Wi-iQ provide real time status of
battery’s condition.
The information is transferred to the PC via USB by Wireless
communication.
1. Operation
The Wi-iQ is suitable for use on all battery technologies
voltage range is 12v – 120v.
The device records global data during the life of the battery.
It will store data for 2,555 cycles (complete history stored by
PC). The data can be analysed by the PC software program:
state of charge, temperature warnings and low electrolyte
level warnings.
2. Clear visibility
Selecting the Exception & Detailed Reports will provide
information on the condition of your battery and any actions
that are necessary. Wi-iQ Report will quickly enable you to
get a handle on your battery fleet charging & discharging
characteristics. With information by battery family (truck
type) you can see depth of discharge charts, cycles, charging
and much more.
3. Very easy to use
Plug in USB modem to the PC, scan the Wi-iQ and up-load
the data. Wi-iQ Report is a PC Software running on Windows
7, 8, XP or Vista. A USB wireless key is used for downloading
Wi-iQ data in to a SQL database.
Wi-iQ
®
(optional accessory)
Tricolour LED Blue LED
Back to the manufacturer!
Batteries with this sign must be recycled.
Batteries which are not returned for the recycling process must be disposed of as hazardous waste!
When using motive power batteries and chargers, the operator must comply with the current standards, laws,
rules, and regulations in force in the country of use!
www.enersys.com 05.2018
Subject to technical modification without any prior notice. E.&O.E.