COMPONENT MAINTENANCE MANUAL
BA27
24-01-01
T
h
is docum
ent
contains D
a
ta
control
led by th
e U.S. Export Admini
str
a
tion
Reg
u
lati
ons. Di
versio
n or use
contrary to U.S. law is
proh
ibit
ed
(6)
If the discharge duration is greater than 60 minutes, recharge the battery in
accordance with paragraph H, ensure the battery is clean and issue for use.
(7)
If the discharge duration is less than 60 minutes, recharge the battery as
detailed in paragraph H.
(8)
On completion of the charge, allow the battery to stand open circuit for a
minimum of 4 hours for the battery volts to stabilise.
(9)
Conduct a further discharge test as described in paragraph F (5)(c).
(10) If the discharge duration is now in excess of 60 minutes, recharge the battery
in accordance with paragraph H. Ensure the battery is clean and issue for
use.
(11)
If the discharge duration is still below 60 minutes, reject the battery in
accordance with paragraph J of this maintenance manual.
G.
Commissioning Capacity Test
(1)
Discharge the battery at 5 amps to an end voltage of 20.0 volts.
(2)
If the discharge duration is greater than 60 minutes, recharge the battery in
accordance with paragraph H, ensure the battery is clean and issue for use.
(3)
If the discharge duration is less than 60 minutes, recharge the battery as
detailed in paragraph H.
(4)
On completion of the charge, allow the battery to stand open circuit for a
minimum of 4 hours for the battery volts to stabilise.
(5)
Conduct a further discharge test as described in step (1).
(6)
If the discharge duration is now in excess of 60 minutes, recharge the battery
in accordance with paragraph H. Ensure the battery is clean and issue for
use.
(7)
If the discharge duration is still below 60 minutes, reject the battery in
accordance with paragraph J of this maintenance manual.
Page 13
June 09/06
Page 13
Mar 13/17