ENERSYS Ltd, NEWPORT
COMPONENT MAINTENANCE MANUAL
LEARJET PART NO.7624308001-003
ELN PART NO.9750R0824-Rev04
(7)
If the discharge duration is less than 48 Minutes, recharge in
accordance with section 4.E.
(a)
Carry out a further discharge test in accordance section 4.F
(b)
If the discharge duration is now at least 48 Minutes, recharge in
accordance with section 4.E, ensure the battery is clean and
issue for service.
(c)
If the discharge duration is less than 48 Minutes, reject the
battery.
I.
Rejection
Procedure
If the battery fails to attain the appropriate discharge duration after two
discharge tests, it should be rejected for aircraft use.
J.
Disposal
Lead-Acid batteries contain some hazardous materials and should be
disposed of in accordance with local regulations.
For advice on disposal in the UK, contact :-
Enersys
Limited
Stephenson
Street
NEWPORT
South
Wales
NP19 4XJ
U.K.
Telephone: +44 (0) 1633 277673
Fax:
+44
(0)
1633
281787
Page 108
24-01-03
Aug 25/04