ENERSYS Ltd, NEWPORT
COMPONENT MAINTENANCE MANUAL
LEARJET PART NO.7624308001-003
ELN PART NO.9750R0824-Rev04
(5)
If the open circuit voltage is below 25.3 volts
(a)
Charge in accordance with section 4.E.
(b)
Carry out a discharge test in accordance section 4.F.
(c)
If the discharge duration is at least 48 Minutes, recharge in
accordance with section 4.E., ensure the battery is clean and
issue for service.
(d)
If the discharge duration is less than 48 Minutes, recharge in
accordance with section 4.E.
(e)
Carry out a further discharge test in accordance section 4.F.
(f)
If the discharge duration is now at least 48 Minutes, recharge in
accordance with section 4.E ensure the battery is clean and
issue for service.
If the discharge duration is less than 48 Minutes, reject the
battery.
H.
Servicing
(1)
Visually inspect the exterior of the battery casing for signs of damage,
cracks, corrosion, etc.
(2)
Examine the battery terminal connector for signs of corrosion, damage
and water/dirt ingress; clean if necessary.
(3)
Check and record the open-circuit voltage.
(4)
Recharge in accordance with section 4.E
(5)
Carry out a discharge test in accordance section 4.F
(6)
If the discharge duration is at least 48 Minutes, recharge in accordance
with section 4.E., ensure the battery is clean and issue for service.
Page 107
24-01-03
Apr 21/99