ENERSYS Ltd, NEWPORT
COMPONENT MAINTENANCE MANUAL
LEARJET PART NO.7624308001-003
ELN PART NO.9750R0824-Rev04
D.
Storage
It is recommended that the fully charged battery should be stored in a cool dry
place, ideally below 25
°
C (77
°
F). The battery charge retention will be reduced
with increased temperature.
The graph in Figure 6 demonstrates typical capacity retention of the battery
during storage without regular boost charges.
Charge Retention During Storage at 20°C
Figure
6
The battery may be stored up to 5 years without degradation of performance
provided that an inspection and open circuit voltage check is conducted every
12 months. When stored in temperatures in excess of 35°C (95°F), the
battery should be inspected every 6 months. If the Open-circuit Voltage falls
below 25.3V the battery should be charged in accordance with Section 4. E.
Page 104
24-01-03
Aug 25/04
25.0
25.1
25.2
25.3
25.4
25.5
25.6
25.7
25.8
25.9
26.0
0
1
2
3
4
5
6
7
50
55
60
65
70
75
80
85
90
95
100
Open
Circuit
Voltage
+10°C
+20°C
+30°C
+40°C
Years
Approx
% state
of