20
Doc
L4540
_a
8.15 Data Recording Screen
Figure 33: Data Recording Screen Details
Through this screen the operator can record the
movement data of local mode into an external drive.
In this screen the following elements are shown (refer to
Figure 33):
1. Recording method: Select the recording method
(manual or automatic) for recording movement
data purpose. When manual option is selected, the
system will record only when the user pushes the
record button. When automatic mode is selected,
the system will automatically record the data when
the system is moving.
2. Time period: The user must type the frequency of
the data recording. The units used are seconds.
3. Recording button: Push this button to start/
pause recording the movements’ data in the drive
selected. When the button is yellow, the recording
is paused and when it is green, the recording is
running. If the system detecs any recording failure,
icon will be red.
Figure 34: Recording Buttons Details
8.16 Language Screen
Figure 35: Language Screen Details
The user can choose the alarms language in this screen.
Select the language desired and tap the back button to
go to the main screen.
8.17 Users Screen
Figure 36: Users Screen Details
In this screen the user can create and set several users
to manage the system. The following elements are
shown:
1. User: The operator must tap the cell of the table
and type a new user. The system will inquire an ID
and Password to log into each user profile.
- Operator: This user has general access to operate
the system. To access this user, it is required to
enter the ID “enerpac” and password “100”.
- Expert: The expert has same access rights as
the operator but can also access and operate the
Pressure Sensor Calibration screen (see paragraph
8.8) and special parameters within the Work
Parameters screen (see paragraph 8.3.1). This
actions require a more advanced user because
they are parameters that can completely affect
the functionality of the equipment. To access this
user, it is required to enter the ID “parameter” and
password “200”.
- Administrator: This user is for use by factory
authorized technicians only.
2. Password: In this column the operator must tap
and type the password of each user (refer to point
1 of this section).
3. Group: The operator must tap and choose a group
name for that user.
4. Logoff time: The operator must tap and type the
number of minutes to log off the system with that
user.
3
1
2
1
2
3